SECTION 5 - JLG CONTROL SYSTEM

5-8

– JLG Lift–

3121639

2-5

250

FUNCTION PREVENTED

251

ELEV ANGLE SESOR FAULTY - VOLTAGE OUT OF RANGE
The sensor signal input voltage is outside acceptable range. This could be a short to IGN, short to B+, short to ground, or sensor
not properly mounted.

2512

ELEV ANGLE SENSOR NOT DETECTING CHANGE
Platform elevated for 5 sec. and elevation voltage change not detected. Fault sensor, wire harness, or ground module. Return
platform to stowed position to clear. Reset Model or recalibrate elev angle sensor

252

ELEV ANGLE SENSOR HAS NOT BEEN CALIBRATED
Calibrate elevation rotary sensor using calibration procedure.

2535

SHORT DETECTED ON IGNITION WIRING - CHECK HARNESS
A short to ground has been detected on one of the following: J2-21, J2-22, J2-23, J2-27, J2-28, J3-7, J3-10, J5-5

2536

ALL FUNCTIONS PREVENTED - FUNCTION CUTOUT ACTIVE
Machine Setup’s FUNCTION CUTOUT is set for "2 = ALL FUNCTIONS" and Ground Module J2-11 is de-energized by an exter-
nal safety device.

2537

DRIVE & LIFT UP PREVENTED - FUNCTION CUTOUT ACTIVE
Machine Setup’s FUNCTION CUTOUT is set for "1 = DRV & LFT UP" and Ground Module J2-11 is de-energized by an external
safety device.

2538

FUNCTION PREVENTED - CHARGER CONNECTED
Disconnect AC line from charger to clear fault.

255

PLATFORM OVERLOADED
Machine Setup’s LOAD is set to "1 = CUTOUT PLT" or "2 = CUTOUT ALL" and the Load Sensing System indicates that the plat-
form is overloaded.

257

ELEV PROX PERMANENTLY CLOSED - CHECK PROX AND ANGLE ADJUSTMENT
Elevation proximity sensor closed. This could be due to a misadjustment of the prox or angle mount sensor or metal debris on
the prox.

N/A

ELEV PROX PERMANENTLY OPEN - CHECK PROX AND ANGLE ADJUSTMENT

3-1

310

LINE CONTACTOR OPEN CIRCUIT

311

OPEN CIRCUIT LINE CONTACTOR
Line contactor did not close.

313

OPEN CIRCUIT PUMP CONTACTOR
Pump contactor did not close.

3-2

320

LINE CONTACTOR SHORT CIRCUIT

321

LINE CONTACTOR MISWIRED ON OR WELDED
The line contactor is permanently closed or the coil is wired improperly.

323

PUMP CONTACTOR MISWIRED ON OR WELDED
The pump contactor is permanently closed or the auxiliary contacts are wired improperly.

3-3

330

GROUND OUTPUT DRIVER

33330

SHORT CIRCUIT LINE/PUMP CONTACTOR COIL
The line or pump contactor coils are shorted to ground or mis-wired.

4-2

420

THERMAL LIMIT

421

POWER MODULE TOO HOT - PLEASE WAIT
The power module over the rear axle is too hot. Allow to cool by powering down.

425

POWER CONVERTER TOO HOT - PLEASE WAIT
Switching power supply in ground control box too hot. Allow to cool by powering down to clear fault.

Table 5-1. Flash Codes/DTC’s

FLASH CODE

DTC

HELP MESSAGE AND DESCRIPTION