6 engine (43x), 7 battery supply (44x), Engine (43x) – JLG 4017RS Service Manual User Manual
Page 198: Battery supply (44x), Electrical system

Electrical System
9-46
3614RS, 4017RS
9.13.6
Engine (43X)
9.13.7
Battery Supply (44X)
Message
Fault
Code
Indicators
Other Actions Taken
Trigger for Fault
Latch Until
ENGINE
43XXX
-
-
-
-
ALTERNATOR
CHARGING FAILURE
4320
5000Ms
–
Engine running > 3,000Ms and UGM
J4-7 Alternator D+ digital input is
low
UGM J4-7
Alternator D+
is high for
3,000Ms
Message
Fault
Code
Indicators
Other Actions Taken
Trigger for Fault
Latch Until
BATTERY SUPPLY
44XXX
-
-
-
-
BATTERY VOLTAGE
TOO LOW – SYSTEM
SHUTDOWN
441
-
Hydraulic functions are prevented
All digital outputs are disabled
UGM detects the battery voltage is <
9V for at least 500Ms; engine is not
cranking
Power cycled
BATTERY VOLTAGE
TOO HIGH – SYSTEM
SHUTDOWN
442
-
Hydraulic functions are prevented
All digital outputs are disabled
UGM detects the battery voltage >
16V for at least 250Ms
Power cycled
BATTERY VOLTAGE
LOW
445
5000Ms
–
UGM detects battery voltage < 11V
for 3,000Ms, and the engine is
running
UGM detects
battery voltage
>11V for
10,000Ms
REFERENCE VOLTAGE
OUT OF RANGE –
GROUND
447
5000Ms
Hydraulic functions are prevented
UGM detects its reference voltage is
out of range (>5.4V or <4.6V) for
1000Ms.
Power cycled