Binary value decimal value description, Port modes, Gsm basic parameters – 2N BRI Lite/Enterprise v1.1 User Manual
Page 67
67
Receive dial number from Subaddress – use this parameter to receive dialling
from the subaddress element instead of standard CDN.
Don‟t send Connect ACK on TE – use this parameter to enable/disable sending
of the CONNECT ACK message to the TE port.
BRI LINE MONITORING
Tone signalling for calls from ISDN
Dial tone to BRI1 with empty SETUP – set the dial tone type to be generated
by the BRI gateway.
Ring tone – set the ring tone type to be generated by the BRI gateway.
Generate busy tone to BRI1 – set the busy tone type to be generated by the
BRI gateway into the BRI 1 interface.
Generate busy tone to BRI2 - set the busy tone type to be generated by the
BRI gateway into the BRI 2 interface.
Numbering plan settings
CDN, CGN – use these parameters to set the Numbering plan for the called
(CDN) and calling (CGN) numbers.
Binary value
Decimal value
Description
0000
0
Unknown numbering plan
0001
1
ISDN/Telephony numbering plan
0011
3
Sata numbering plan
0100
4
Telex numbering plan
1000
8
National standard numbering plan
1001
9
Private numbering plan
1111
15
Reserved for Extension
Port modes
This item helps you set each of your gateway ports. The settings are based on the LCR
table including relevant routing/rejecting rules for all incoming and outgoing calls.
GSM basic parameters
Number of digits dialled from VoIP
Minimum numbers from VoIP – set the minimum count of digits to be dialled
into the GSM network.
Maximum numbers from VoIP – set the maximum count of digits to be dialled
into the GSM network.
Wait for next digit [s] – set the timeout for 2N BRI gateway to wait for the
next digit dialled from VoIP to GSM.
Calls