Final set-up – Condux Deluxe Blower User Manual
Page 27

10. Choose the correct
Cable Seals and install on cable. Grooved side of Cable
Seal faces conduit. Place Cable Seals into Venturi, split side down
(Figure 55).
11. Close
Air Block Cover (Figure 56). Tighten nuts securely, but do not over
tighten. Use cross tightening procedure to completely secure.
Final Set-Up
1.
Lower Tractor Drive Cover with turn crank until the cover reaches the stopper-
bushing. The stopper-bushing will prevent the tractor cover from being clamped
too tightly on the cable (Figure 57).
2. Level the height of
Air Block’s Venturi Tube with Tractor Drive and the
approximate center line of the cable (Figure 58). Tighten slide cap screws after
adjustments are made.
3. Notify crew that preparations are complete and cable blowing is to begin.
27
11.
Figure 57. Lower Tractor Drive
Cover with Turn Crank
Figure 58. Level Air Block with
Tractor Drive
10.
Figure 56. Close Air Block Cover
Figure 55. Install Cable Seals