Klein Tools CL200 User Manual

Instruction manual, Cl 200

Advertising
background image

CUSTOMER SERVICE

KLEIN TOOLS, INC.

450 Bond Street

Lincolnshire, IL 60069

1-877-775-5346

[email protected]

www.kleintools.com

139560T Rev. 11/13 B

ENGLISH

• AUTO / MANUAL

RANGE

• DATA HOLD

• 3-1/2 DIGIT

1999 COUNT LCD

• BACKLIGHT

• WORKLIGHT

• TEMPERATURE

ENGLISH

ELECTRICAL SPECIFICATIONS

DC Voltage Measurement

Range

Resolution

Accuracy

400mV

0.1mV

± (0.8% + 2 digits)

4V

0.001V

40V

0.01V

400V

0.1V

600V

1V

± (1.0% + 2 digits)

Overload Protection:

600V DC / AC

Input Impedance:

10M

Ω.

AC Voltage Measurement

Range

Resolution

Accuracy

400mV

0.1mV

± (1.0% + 10 digits)

4V

0.001V

40V

0.01V

400V

0.1V

600V

1V

± (1.2% + 10 digits)

Overload Protection:

600V DC / AC

Frequency:

40 to 400Hz

Input Impedance:

10M

Ω.

Response:

Averaging

AC Current Measurement

Range

Resolution

Accuracy

4A

0.001A

± (3.5% + 20 digits)

0.5A

4A

0.001A

± (3.0% + 10 digits) > 0.5A

40A

0.01A

± (3.0% + 10 digits)

400A

0.1A

± (2.5% + 10 digits)

600A

1A

± (1.5% + 5 digits)

Overload Protection:

720A for 60 sec. max

Frequency:

50 to 60Hz

Response:

Averaging

Resistance Measurement

Range

Resolution

Accuracy

400

Ω

0.1

Ω

± (1.2% + 2 digits)

4k

Ω

0.001k

Ω

40k

Ω

0.01k

Ω

400k

Ω

0.1k

Ω

4M

Ω

0.001M

Ω

40M

Ω

0.01M

Ω

± (2.0% + 5 digits)

Overload Protection:

600V DC / AC

Capacitance Measurement

Range

Resolution

Accuracy

50nF

0.01nF

± (3.0% + 10 digits)

500nF

0.1nF

± (3.0% + 5 digits)

5µF

0.001µF

50µF

0.01µF

100µF

0.1µF

Overload Protection:

600V DC / AC

Frequency Measurement

Range

Resolution

Accuracy

50Hz

0.01Hz

± (0.1% + 3 digits)

500Hz

0.1Hz

5kHz

0.001kHz

50kHz

0.01kHz

100kHz

0.1kHz

Overload Protection:

600V DC / AC

Duty Cycle Measurement

Range

Resolution

Accuracy

0.1 ˜ 99.9%

0.1%

± (3.0% + 0 digits)

Overload Protection:

600V DC / AC

Temperature Measurement

Range

Resolution

Accuracy

-4 ˜ 1832°F

1°F

± (3.0% + 3 digits)

-20 ˜ 1000°C

1°C

± (3.0% + 2 digits)

Overload Protection:

600V DC / AC

Diode Test

Overload Protection

Resolution

Open Circuit Voltage

600V DC / AC

1mV

Appx. 1.5V

Continuity Test

Overload Protection

Resolution

Open Circuit Voltage

600V DC / AC

100m

Ω

Appx. 0.45V

WARRANTY

www.kleintools.com/warranty

CLEANING

Turn instrument off and disconnect test leads. Clean the instrument by using

a damp cloth. Do not use abrasive cleaners or solvents.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period of

time. Do not expose to high temperatures or humidity. After a period of storage

in extreme conditions exceeding the limits mentioned in the Specifications

section, allow the instrument to return to normal operating conditions before

using it.

DISPOSAL / RECYCLE

Caution:

This symbol indicates that equipment and its accessories

shall be subject to a separate collection and correct disposal.

Dwg Name:

CL200-139560TART Dwg No: 139560T

ECO No:

15429 Pkg Dwg Ref: 1650 Rev: B

Color Reference:

N/A

Instruction Manual

CL

200

600A

600V

CL200 Instruction Manuals - MASTER.indd 1-4

12/16/2013 12:16:18 PM

Advertising
Table of contents