Snap-loc 24, Installation of ridge flashing – Metal Sales Snap-Loc 24 Installation User Manual
Page 48
© Metal Sales Manufacturing Corporation / Subject to change without notice. 10/99
47
SNAP-LOC 24
RIDGE FLASHING
The ridge flashing should not be installed until the rake flashing has been installed.
The following procedures are based on installing the SSR Ridge flashing.
DOUBLE BEAD TAPE SEALANT
METAL
OUTSIDE
CLOSURE
3"
9"
INSTALLATION OF RIDGE FLASHING
2. Place SSR Ridge flashing over the rake flashing and the Metal Outside Closure. Make sure that
proper placement of the SSR Ridge flashing is achieved. It is critical that the ridge flashing be
installed correctly to insure a weathertight system.
STEPS
1. Apply a continuous strip of Double Bead Tape Sealant to the top of the Metal Outside Closures at
the ridge starting at the outer edge of the rake flashing.
SSR SCULPTURED RAKE
(OFF MODULE)
SNAP-LOC 24 PANEL
SSR RIDGE
Note:
Minor ribs in Snap-Loc 24 panel
are not shown for clarity reasons.