PI/D-15

I

ndustrIal

r

Ib

/ d

eep

r

Ib

s

erIes

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

T15 s

eCTion

P

roPerTies

ROOF PANEL PROFILE

WALL PANEL PROFILE

C

30" Coverage

4"

10" Pitch

3"

3"

7"

ALLOWABLE UNIFORM LOADS PSF

(3 or More Equal Spans)

5’ 6’ 7’ 8’ 10’ 12’ 5’ 6’ 7’ 8’ 10’ 12’

SECTION PROPERTIES

Bottom in Compression

Width

(in.)

Yield

KSI

30”

50

30”

50

30”

33

30”

33

24

Ga.

22
20
18

Sxx

In

3

/ft

Ixx

In

4

/ft

Weight

PSF

1.42
1.89
2.24
2.95

Top in Compression

Sxx

In

3

/ft

Ixx

In

4

/ft

0.6536

0.2635

0.6340

0.2344 134 103 82 66 46 33 139 109 87 71 50 37

1.0008

0.4404

0.9792

0.3908 268 201 156 124 83 59 285 216 169 135 91 66

1.3480

0.6404

1.3880

0.6137 328 237 179 139 91 64 339 246 185 145 95 67

1.8640

0.9084

1.9400

0.8796 502 357 266 205 133 93 516 367 274 212 137 96

Inward

Load

Outward / Uplift

Load

1. Theoretical section properties have been calculated per AISI 2001. “Specifications for the Design of Cold-formed Steel Structural

Members.” Ixx and Sxx are effective section properties for deflection and bending.

2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear and

deflection. Allowable load considers both 3 or more equal span conditions. Allowable load does not address web crippling or

fasteners/support connection. Panel weight is not considered.

3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.

4. Allowable loads do not include a 1/3 stress increase in uplift.

C

30" Coverage

4"

10" Pitch

3"

7"

3"

ALLOWABLE UNIFORM LOADS PSF

(3 or More Equal Spans)

5’ 6’ 7’ 8’ 10’ 12’ 5’ 6’ 7’ 8’ 10’ 12’

SECTION PROPERTIES

Bottom in Compression

Width

(in.)

Yield

KSI

30”

50

30”

50

30”

33

30”

33

24

Ga.

22
20
18

Sxx

In

3

/ft

Ixx

In

4

/ft

Weight

PSF

1.42
1.89
2.24
2.95

Top in Compression

Sxx

In

3

/ft

Ixx

In

4

/ft

0.6340

0.2344

0.6536

0.2635 139 109 87 71 50 37 134 103 82 66 46 33

0.9792

0.3908

1.0008

0.4404 285 216 169 169 91 66 268 201 156 124 83 59

1.3880

0.6137

1.3480

0.6404 339 246 185 185 95 67 328 237 179 139 91 64

1.9400

0.8796

1.8640

0.9084 516 367 274 274 137 96 502 357 266 205 133 93

Inward

Load

Outward

Load

1. Theoretical section properties have been calculated per AISI 2001. “Specifications for the Design of Cold-formed Steel Structural

Members.” Ixx and Sxx are effective section properties for deflection and bending.

2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear and

deflection. Allowable load considers both 3 or more equal span conditions. Allowable load does not address web crippling or

fasteners/support connection. Panel weight is not considered.

3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.

4. Allowable loads do not include a 1/3 stress increase in uplift.

Advertising