Installation, Mantel clearances, Mantel leg clearances – Regency Horizon HZ54E Large Gas Fireplace User Manual
Page 12
12
Regency Horizon HZ54E-1 Gas Fireplace
INSTALLATION
MANTEL CLEARANCES
Due to the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in
Note: Ensure the paint that is used on the mantel
and the facing is "High Quality" or the paint
may discolour.
MANTEL LEG CLEARANCES
Combustible mantel leg clearances as per diagram:
4"
Allowable mantel
leg projection
5-1/2” (140mm)
8” (203mm)
11” (279mm)
1.5" (38mm)
MANTEL LEG
4”(102mm)
Non-Combustible
7”
Drywall
2
0
12
6
4
8
10
Top of
Fireplace
Opening
13" (330mm)
3 ½" (89mm)
Standoff
Metal Stud
(On Edge)
0
10
20
14
Non-combustible
Facing
To Unit
Base Legs
1" (25mm)
30”
20”
21”
28-1/8”
Combustible Material
30
the diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing
is made of metal studs covered with a
non-combustible board.