Installation, Vent restrictor position – Regency Horizon HZ54E Large Gas Fireplace User Manual
Page 16
16
Regency Horizon HZ54E-1 Gas Fireplace
INSTALLATION
Vent restriction is required for certain venting installations, see the diagrams in the "Venting
Arrangements" section to determine if they are required for your installation.
The Vent Restrictor plate is located on the inside top of the fi rebox.
To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;
1) Remove the glass door.
2) Remove the screws that hold the vent restrictor plate in place.
3) Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown.
4) Once the vent restrictor plate is in the required position, secure with screws.
VENT RESTRICTOR POSITION
V
ent Restrictor Settings for HZ54E-NG
V
ent Restrictor Settings for HZ54E-LP
4.25”
3”
2”
Vent Restrictor Set 1
Factory Set Vent Restrictor
(No adjustment required)
Vent Restrictor Set 2
Vent Restrictor Set 4
SET 2
THIS HOLE SETS THE
VENTR ESTRICTOR
AT 3”
SET 1
THIS HOLE SETS THE
VENTR ESTRICTOR
(factory setting)
AT 4.25”
SET 4
THIS HOLE SETS THE
VENTR ESTRICTOR
AT 2”
Vent Restrictor Set 3
SET 3
THIS HOLE SETS THE
VENTR ESTRICTOR
AT 2-1/2”
2.5”
4.25”
2”
1”
Vent Restrictor Set 1
Factory Set Vent Restrictor
(No adjustment required)
Vent Restrictor Set 4
Vent Restrictor Set 5
SET 1
THIS HOLE SETS THE
VENT RESTRICTOR
(factory setting)
AT 4.25”
SET 4
THIS HOLE SETS THE
VENT RESTRICTOR
AT 2”
SET 5
THIS HOLE SETS THE
VENT RESTRICTOR
AT 1”