Toggle switch installation – Wolo 416 Euro Emergency Horn User Manual
Page 2
ELECTRICAL CONNECTIONS FOR A NEW HORN BUTTON SWITCH:
Install the relay in a dry location with the terminals facing downward near the compressor. Refer to Figure 4 for wiring.
A. Connect relay terminal 87 to
the positive terminal at the
bottom of the compressor. Use
no less than a 16-gauge wire.
B. Connect relay terminal 85 to
the horn switch terminal. The
other horn switch terminal is
connected to ground (body of
vehicle). An 18-gauge wire is
suggested for this connection.
C. Connect relay terminals 30/86
to positive (+) 12-volt battery,
alternator or accessories. Use
16-gauge or heavier wire. A
20-ampere fuse is suggested
to be installed as shown in
Figure D.
TOGGLE SWITCH INSTALLATION
The toggle switch included in kit, will control the horn’s tone:
Steady Tones / Euro Hi-Lo Tone.
A. Mount the toggle switch in an accessible place inside the vehicle.
B. One terminal of the toggle switch is connected to the compressor’s side
terminal. Use insulated terminal provided to make connection (Figure 5).
C. The other toggle switch terminal is connected to the positive (+) terminal
at the bottom of the compressor. (Figure 5)
Warranty
Wolo Manufacturing Corporation (“Wolo”) warranties to the original purchaser, for three months from the date of purchase, that
this product is free from defects in workmanship and materials. If there is such a proven defect, Wolo, at its option, will either
repair or replace the item free of charge, if it is returned to Wolo within three months from the date of purchase together with
proof of purchase as described below. Wolo reserves the right to inspect any defect prior to settling any warranty claim by repair
or replacement. This warranty is limited as above provided and Wolo will not be responsible for fire or other casualty or accident,
due to neglect, abuse, abnormal use, modifications, faulty installation of this product, or natural causes.
ANY EXPRESSED WARRANTY NOT PROVIDED HEREIN IS EXCLUDED AND DISCLAIMED. THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY LIMITED TO A TERM OF THREE (3)
MONTHS. UNDER NO CIRCUMSTANCES SHALL WOLO BE LIABLE TO PURCHASER OR ANY OTHER PERSON FOR ANY
SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER ARISING OUT OF BREACH OF WARRANTY OR OTHERWISE.
To obtain warranty service, return the product prepaid, and include the original bill of sale showing the date of purchase. Provide with
the return a brief description of the problem. Also, include with the return a check or money order in the amount of $10.00 to cover
return shipping. Mail to:
Wolo Manufacturing Corp.
One Saxwood Street, Deer Park, NY 11729
Attn: Warranty Service
E-mail: [email protected]
Fig. 5
Fig. 4
COMPRESSOR
RELAY
HORN SWITCH
GROUND
BATTERY
GROUND
20 AMP FUSE
RECAP OF TERMINAL CONNECTIONS
Terminals 30/86: the two (2) terminals are connected to 12-volt positive (+) using a fuse.
Terminal 85: connect horn switch negative (-).
Terminal 87: connect positive (+) terminal of compressor.
© 2006 Wolo Mfg. Corp All Rights Reserved.