Get/set, Uint, Bool – Rockwell Automation 825-P Modular Protection System for Motors User Manual User Manual
Page 263: Usint, Word, 0…0x00ff, 0…ffff

Rockwell Automation Publication 825-UM004D-EN-P - April 2012
263
DeviceNet Information Chapter E
Attribute ID
Access
Rule
Name
Data
Type
Min/Max
Default
Description
7
Get/Set
Prod Assy Word 0
UINT
1
Defines Word 0 of Assy 100
8
Get/Set
Prod Assy Word 1
UINT
5
Defines Word 1 of Assy 100
9
Get/Set
Prod Assy Word 2
UINT
6
Defines Word 2 of Assy 100
10
Get/Set
Prod Assy Word 3
UINT
7
Defines Word 3 of Assy 100
15
Get/Set
Autobaud Enable
BOOL
0…1
1
1= enabled; 0 = disabled
16
Get/Set
Consumed Assy
USINT
0…185
150
17
Get/Set
Produced Assy
USINT
0…185
103
19
Get/Set
Set To Defaults
BOOL
0…1
0
0=No action; 1=Reset
23
Get
I/O Produced Size
USINT
0…16
Read only
24
Get
I/O Consumed Size
USINT
0…8
Read only
30
Get
DeviceNet Voltage
UINT
Read only
50
Get/Set
PNB COS Mask
WORD
0…0x00FF
0
Change of state mask for PNBs
55
Get/Set
Prod Assy Word 4
UINT
0
Defines Word 4 of Assy 100
56
Get/Set
Prod Assy Word 5
UINT
0
Defines Word 5 of Assy 100
57
Get/Set
Prod Assy Word 6
UINT
0
Defines Word 6 of Assy 100
58
Get/Set
Prod Assy Word 7
UINT
0
Defines Word 7 of Assy 100
65
Get/Set
Status COS Mask 1
UINT
0…ffff
0
66
Get/Set
Status COS Mask 2
UINT
0…ffff
0
67
Get/Set
Trip COS Mask 1
UINT
0…ffff
0
68
Get/Set
Trip COS Mask 2
UINT
0…ffff
0
69
Get/Set
Warning COS Mask 1
UINT
0…ffff
0
70
Get/Set
Warning COS Mask 2
UINT
0…ffff
0