Rockwell Automation 20G PowerFlex 750-Series Power Jumpers User Manual
Page 7

Rockwell Automation Publication 750-IN011E-EN-P - February 2014
7
PowerFlex 750-Series Power Jumpers
8…10
C
D
E
F
PE-A1 & PE-A2
connected to ground.
PE-B jumper plug
insulated/
disconnected from
ground.
PE-A1, PE-A2 and PE-
B connected to
ground.
Solid Ground
Connect the MOV jumper wire (PE-A1), Input Filter
Cap jumper plug (PE-A2) and the CM Cap jumper
plug (PE-B) to ground.
See
for recommended torque.
Non-Solid Ground
Insulate/disconnect the MOV jumper wire (PE-A1), Input
Filter Cap jumper plug (PE-A2) and the CM Cap jumper plug
(PE-B) from ground.
Frame
Vo
lt
ag
e
Co
de
Factory Default Jumper Settings
Power Source Type
Catalog Code “A”
Catalog Code “J”
PE-A1
PE-A2
P3
P2
PE-A1
Insulated (P2)
Connected (P3)
Insulated
Connected
Insulated (J4)
Connected (J3)
PE-A1 and GND positions on
early production drives.
1.86 N•m (16.0 lb•in)
Insulated
Connected