Motor encoder interface circuit, Hall effect sensor circuit, J2- motor encoder connector pin-outs – Rockwell Automation 1398-DDM-xxx USE MNL/ULTRA 200 DIG.SERVO.DR User Manual
Page 92

Publication 1398-5.0 – October 1998
6-28
Interfaces
Figure 6.34
Motor Encoder Interface Circuit
Intro
Figure 6.35
Hall Effect Sensor Circuit
Intro
1K
-
+
26LS33
AM(-)
1K
220pF
AM
220pF
AM(+)
1K
200
.01uF
1K
LINE
BREAK
DETECT
Drive
J2
-
+
AM26C31
200
+2.5V
U,
1K
Drive
J2
+5V
V or
W
Table 6.22:
J2- Motor Encoder Connector Pin-Outs
Motor Encoder
Pin Number
Description
EPWR
J2-1
J2-3
Encoder power
Internally fused (F3) is 1A, fast acting.
ECOM
J2-2
J2-4
Encoder common
SENSE (+)
SENSE (-)
J2-5 (+)
J2-6 (-)
Encoder power sense
NOTE: The SENSE+ signal must be connected to the EPWR sig-
nal, and the SENSE- signal must be connected to the ECOM sig-
nal at the encoder for the motor encoder signals to be received
properly by the drive.
A(+)
A (-)
J2-7 (+)
J2-8 (-)
Motor Encoder Input Channel A(+) and Channel A(-). Accepts TTL
level signals from a line driver.
B(+)
B (-)
J2-9 (+)
J2-10 (-)
Motor Encoder Input Channel B(+) and Channel B(-). Accepts TTL
level signals from a line driver.
I (+)
I (-)
J2-11 (+)
J2-12 (-)
Motor Encoder Input Channel I(+) and Channel I(-). Accepts TTL
level signals from a line driver. Output pulse occurs once per motor
shaft revolution.