Display the waterfall plot – Rockwell Automation 1441-DYN25-MRUC Run Up Coast Down Extension Module for the Dynamix 2500 User Manual
Page 33

Rockwell Automation Publication 1441-UM006A-EN-P - May 2011
33
Run Up/Coast Down Extension Module Chapter 2
Display the Waterfall Plot
When you are finished setting up the plot parameters, you can process the
spectral data by pressing F3 (Display) on the RUCD - Waterfall Setup screen.
Optimize the Waterfall Plot
Additional parameters display on the screen letting you to control how the
spectra appear in the waterfall plot.
1.
Select the option and press the Right arrow to open a list of values.
2.
Select or type in a parameter value.
3.
Press the Left arrow to save your selection.
Use the descriptions in
Waterfall Plot Setup Parameters on page 34
to help
you configure the parameters.
LF Cutoff (EU)
Sets a low frequency cutoff filter to remove noise from the analysis.
The available options are determined by the X-axis selection.
Off
21.6 CPM
66 CPM
120 CPM
600 CPM
4200 CPM
.36 Hz
1.1 Hz
2 Hz
10 Hz
70 Hz
Table 7 - Waterfall Plot Parameters
Parameter Name
Description
Values/Comments
TIP
The larger the .wav file, the longer it takes to process the data
and display the plot.