Cable categories for the 8720mc system, Cable categories for the 8720mc system -18 – Rockwell Automation 8720MC High Performance Drives Installation Manual User Manual
Page 30

Publication 8720MC-IN001D-EN-P — December 2002
1-18
Installing Your 8720MC Drive
Cable Categories for the 8720MC System
The table below indicates the zoning requirements of cables
connecting to the 8720MC drive.
The table below indicates the zoning requirements of cables
connecting to the 8720MC-RPS.
Wire/Cable
Connector
Zone
Method
Very
Dirty
Dirty
Clean
Ferrite
Sleeve
Shielded
Cable
All 3-phase AC from filter to AC drive
(shielded option)
TB1
X
X
All 3-phase AC from filter to AC drive
(unshielded option)
TB1
X
DC power
TB1
X
X
Motor Power
TB1
X
X
Relay Output (0-3)
P5
X
Digital Output (0-5)
P5
X
Digital Input (0-9)
P5
X
Encoder input
P1
X
X
Analog Input
P1
X
X
Analog Output
P4
X
X
Registration input
P4
X
X
Buffered encoder output
P5
X
X
Wire/Cable
Connector
Zone
Method
Very
Dirty
Dirty
Clean
Ferrite
Sleeve
Shielded
Cable
All 3-phase AC from filter to Converter
(shielded option)
TB1
X
X
All 3-phase AC from filter to Converter
(unshielded option)
X
DC power
X
X
DC power
X
120V ac power
TB2
X
Run Input
TB3
X
External Fault Input
X
Digital Comm input
X
Fault Reset
X
Fault Output
X
VSC Run Output
X