Power wiring, Power wiring -14 – Rockwell Automation 20D PowerFlex 700H and 700S Frame 9-14 Drives Installation - A4 Size User Manual
Page 128
Advertising

9-14
Frame 12 Installation
Power Wiring
Input Power Wiring
Frame 12 drives utilize two parallel power structures, and therefore have
two sets of AC input power terminals. You must supply power to both sets
of input terminals. There are several methods for accomplishing this.
Important: Parallel wiring must have the same cable dimensions, type and
routing. Non-symmetrical wiring may cause unequal loading
between the converters and reduce the drive’s ability to deliver
current to the motor.
Figure 9.4 Frame 12 AC Wiring Example: Two Fuses per Phase
1L1
1L2
1L3
2L1
2L2
2L3
L1
L2
L3
AC Input Power Terminals
Inside Drive
AC Input Power Wiring, Fuses, and
Disconnect Device Provided by
Customer