Table 52, 600 – Rockwell Automation 1336T Wiring and Grounding Guide, (PWM) AC Drives User Manual
Page 121

Rockwell Automation Publication DRIVES-IN001M-EN-P - March 2014
121
Motor Cable Length Restrictions Tables Appendix A
1350
2
12.2
(40)
30.5
(100)
76.2
(250)
106.7
(350)
12.2
(40)
45.7
(150)
91.4
(300)
121.9
(400)
61.0
(200)
152.4
(500)
304.8
(1000)
365.8
(1200) 2 x
1321-3R850-B
20
600
4
7.6
(25)
24.4
(80)
45.7
(150)
76.2
(250)
12.2
(40)
30.5
(100)
76.2
(250)
106.7
(350)
45.7
(150)
121.9
(400)
243.8
(800)
304.8
(1000)
20
1200
1750
2
12.2
(40)
30.5
(100)
76.2
(250)
91.4
(300)
12.2
(40)
45.7
(150)
91.4
(300)
121.9
(400)
45.7
(150)
137.2
(450)
304.8
(1000)
365.8
(1200) 3 x
1321-3R850-B
30
500
(6)
4
7.6
(25)
24.4
(80)
45.7
(150)
76.2
(250)
12.2
(40)
30.5
(100)
76.2
(250)
106.7
(350)
30.5
(100)
106.7
(350)
213.4
(700)
304.8
(1000)
30
1000
(1) Frame 9 and Frame 10 drives require two or three parallel reactors to match drive amp rating. The resistor ratings are per phase values for each reactor.
(2) Resistor specification is based on two parallel cables per phase.
(3) Resistor specification is based on three parallel cables per phase.
(4) Resistor specification is based on four parallel cables per phase.
(5) Resistor specification is based on five parallel cables per phase.
(6) Resistor specification is based on six parallel cables per phase.
Table 51 - PowerFlex 755 Floor Mount Drives, 480V Shielded/Unshielded Cable – Meters (Feet) (continued)
Drive Rating
No Solution
Reactor Only
Reactor and Damping Resistor Reactor
Resistor
Available Options
Frame Hp
kHz 1000V 1200V 1488V 1600V 1000V 1200V 1488V 1600V 1000V 1200V 1488V 1600V Cat. No.
Ohms Watts
TF
A1
TF
B
2
RW
R2
RW
C
Table 52 - PowerFlex 755 Floor Mount Drives, 600V Shielded/Unshielded Cable – Meters (Feet)
Drive
Rating
No Solution
Reactor Only
Reactor and
Damping Resistor
Reactor
Resistor
Available Options
Frame
HP
kHz
1488V 1850V 1488V
1850V
1488V
1850V
Cat. No.
Ohms
Watts
TFA1
TFB2
RWR2
RWC
8
300
2
24.4
(80)
137.2
(450)
61.0
(200)
152.4
(500)
167.6
(550)
365.8
(1200)
1321-3RB400-B
50
315
●
4
24.4
(80)
106.7
(350)
61.0
(200)
121.9
(400)
121.9
(400)
198.1
(650)
50
630
350
2
24.4
(80)
91.4
(300)
61.0
(200)
152.4
(500)
167.6
(550)
365.8
(1200)
1321-3RB400-B
20
585
(2)
●
4
24.4
(80)
91.4
(300)
61.0
(200)
121.9
(400)
121.9
(400)
213.4
(700)
20
1170
400
2
24.4
(80)
91.4
(300)
61.0
(200)
152.4
(500)
167.6
(550)
365.8
(1200)
1321-3R500-B
20
585
●
4
24.4
(80)
91.4
(300)
61.0
(200)
121.9
(400)
121.9
(400)
213.4
(700)
20
1170
450
2
24.4
(80)
91.4
(300)
61.0
(200)
152.4
(500)
167.6
(550)
365.8
(1200)
1321-3R500-B
20
585
●
4
24.4
(80)
91.4
(300)
61.0
(200)
121.9
(400)
121.9
(400)
213.4
(700)
20
1170
500
2
24.4
(80)
91.4
(300)
61.0
(200)
152.4
(500)
167.6
(550)
365.8
(1200)
1321-3R600-B
20
585
●
4
24.4
(80)
91.4
(300)
61.0
(200)
121.9
(400)
121.9
(400)
213.4
(700)
20
1170
continued
- 1336E Wiring and Grounding Guide, (PWM) AC Drives 1336F Wiring and Grounding Guide, (PWM) AC Drives 1336S Wiring and Grounding Guide, (PWM) AC Drives 1336VT Wiring and Grounding Guide, (PWM) AC Drives 1336 Wiring and Grounding Guide, (PWM) AC Drives 1305 Wiring and Grounding Guide, (PWM) AC Drives 25B Wiring and Grounding Guide, (PWM) AC Drives 20N Wiring and Grounding Guide, (PWM) AC Drives 20M Wiring and Grounding Guide, (PWM) AC Drives 22C Wiring and Grounding Guide, (PWM) AC Drives 22B Wiring and Grounding Guide, (PWM) AC Drives 22A Wiring and Grounding Guide, (PWM) AC Drives 20D Wiring and Grounding Guide, (PWM) AC Drives 20C Wiring and Grounding Guide, (PWM) AC Drives 20B Wiring and Grounding Guide, (PWM) AC Drives 20A Wiring and Grounding Guide, (PWM) AC Drives 1336R Wiring and Grounding Guide, (PWM) AC Drives