Watts S1513-14 User Manual
Stainless series
8550 Hansen Road
•
Houston, Texas 77075
•
(Ph) 713.943.0688
•
(Fx) 713.944.9445
•
www.wattsacv.com
01/05
R
Stainless Series
DEEP WELL PUMP CONTROL
VALVE with PRESSURE
RELIEF FEATURE
3
4
X/Y
6
2
5
(Supply Pressure)
CLOSES VALVE
OPENS VALVE
FLOW
1
X
Y/FC
X
X
X
X
• Installed on branch of tee off main pumping header
• Normally open construction
• Discharges to atmosphere on pump start-up
• Closes slowly diverting pressure into system during
pumping cycle
• Opens slowly on pump shut-off
• Limit Switch turns pump off when valve is fully open
• Pressure Relief Feature protects system during
pumping cycle
• Adjustable Opening and Closing Speed
• Solenoid equipped with Manual Operator
• Relief setpoint is adjustable
1 - Main Valve (Dual Chamber)
2 - Limit Switch
3 - 4-Way Solenoid
4 - Adjustable Closing Speed
5 - Adjustable Opening Speed
6 - Pressure Relief Control
°
X - Isolation Cocks (STANDARD)
°
L - Dual Limit Switch
STANDARD COMPONENTS
OPTIONS and ACCESSORIES
S513-14 or S6513-14 (Globe)
S1513-14 or S61513-14 (Angle)
s513-14 link