Headloss

Flow Rate - Gallons per minute (Water)

Pressure Drop (psi)

Angle
Globe

2

4

6 8 10

20

40

60 80 100

200

500

1000

2000

5000

10000

20000

100

80

60

40

30

20

10

8

6

4

3

2

Maximum continuous flow based on velocity of 20 ft. per second.
Maximum intermittent flow based on velocity of 25 ft. per second.
The C

v

Factor of a value is the flow rate in US GPM at 60°F that will cause a 1psi drop in pressure.

The factors stated are based upon a fully open valve.
C

v

factor can be used in the following equations to determine Flow (Q) and Pressure Drop (∆P):

Q (Flow) = C

v

√∆P ∆P (Pressure Drop) = (Q/C

v

)

2

ES-ACV-M500-M5100 1219

© 2012 Watts

USA: Tel. (713) 943-0688 • (713) 944-9445 • www.watts.com

A Watts Water Technologies Company

M500 / M1500 — Full Port Ductile Iron Dual Chamber Basic Valve

Flow Data - ACV M500 (Globe) / M1500 (Angle)

Valve Size - Inches

2

2-1/2

3

4

6

8

10

12

14

16

Maximum Continuous

Flow Rate Gpm (Water)

210

300

485

800

1850

3100

5000

7000

8500

11100

Maximum Intermittent

Flow Rate Gpm (Water)

265

390

590

1000

2300

4000

6250

8900

10800

14100

CV Factor GPM (Globe)

45

75

100

175

490

770

1200

1750

2125

2890

CV Factor GPM (Angle)

57

91

125

215

571

990

1530

2525

2885

3575

Estimated

Valve Cover Chamber Capacity

Valve Size - Inches

2

2-1/2

3

4

6

8

10

12

14

16

fluid oz.

4

10

10

22

70

U.S. Gal

1-1/4

2-1/2

4

6-1/2

9-1/2

Valve Travel

Valve Size - Inches

2

2-1/2

3

4

6

8

10

12

14

16

Travel - Inches

1/2

5/8

3/4

1

1-1/2

2

2-1/2

3

3-1/2

4

2-1/2

4

10

6

8

2

3

12 14 16

2-1/2

4

10

6

8

2

3

12 14 16