Watts WD-SERIES User Manual

Wd series, Pdi certified grease interceptor

Advertising
background image

ES-WD-WD SERIES USA 1304

WD SERIES

Tag:

SPECIFICATION

: Watts Drainage WD Series PDI Certified recessed or floor mounted epoxy coated steel grease interceptor

with gasketed epoxy coated steel skid-proof cover secured with hex head center bolt(s), removable baffle assembly, deep

seal trap with cleanout, external cast iron flow control fitting, and no hub (standard) connections.

PDI Certified Grease

Interceptor

WD Series

4 GPM

4

7 GPM

7

10 GPM

10

Flow Rate (Select One)

Suffix Description

15 GPM

15

20 GPM

20

25 GPM

25

35 GPM

35

50 GPM

50

A

Interceptor

Catalog

Inlet &

WD-4

2"(51)

WD-7

2"(51)

WD-10

2"(51)

Number

Outlet

B

Base to

Center

C

Top to

Center

D

Length

E

Width

F

Height

Grease

Capacity

Lbs

8

14
20

7-3/4"(197)

8-1/2"(216)

8-1/2"(216)

3-1/4"(83)

3-1/2"(89)

3-1/2"(89)

16"(406)

18"(457)

21-3/4"(552)

10"(254)

13"(330)

14"(356)

11"(279)

12"(305)

12"(305)

WD-15

2"(51)

30

10-1/2"(267)

3-1/2"(89)

22"(559)

15"(381)

14"(356)

WD-20

3"(76)

WD-25

3"(76)

WD-35

3"(76)

40

50

70

11-1/2"(292)

12"(305)

14"(356)

3-1/2"(89)

4-1/2"(114)

5"(127)

24"(610)

26"(660)
30"(762)

15-3/4"(400)

16-1/2"(419)

18"(457)

15"(381)

16-1/2"(419)

19"(483)

WD-50

4"(102)

100

16"(406)

5-1/2"(140)

32"(813)

22"(559) 21-1/2"(546)

C

IAPMO

U P C

TM

50

35

25

20

15

10

7

4

Flow

Rate

GPM

-E

Extension

-FC

-O

Inlet & Outlet other than

Standard Size

Options (Select One or More)

Suffix Description

Flange & Clamp Device

-SS

Stainless Steel

-B

Sediment Bucket

-THD Threaded Connections

-HD Heavy Duty (10,000 lb.)

Traffic Cover

D (Length) x E (Width)

Flow Restrictor

w/Vent Connection

Inlet

A

Outlet

C

B

F

-US

Buy American Compliant

Advertising