Watts R12-1200-1 User Manual
Page 5
I. INTRODUCTION
The separation of dissolved solids and water using RO membranes is a pressure driven
temperature dependent process. The membrane material is designed to be as permeable to water
as possible, while maintaining the ability to reject dissolved solids.
The main system design parameters require the following:
Internal flows across the membrane surface must be high enough to prevent settling of fine
suspended solids on the membrane surface.
The concentration of each dissolved ionic species must not exceed the limits of solubility
anywhere in the system.
Pre-treatment must be sufficient to eliminate chemicals that would attack the membrane
materials.
A. SPECIFICATIONS
R12-0150 R12-0250 R12-0600 R12-1200
Maximum Productivity
(Gallons per day)
150 250 600 1200
Quality (membrane rejection)
98 %
98 %
98 %
98 %
Recovery (user adjustable)
15 - 75 %
15 - 75%
15 - 75 %
30 - 75 %
Membrane Size
2.5” x 14” 2.5” x 21” 2.5” x 40” 2.5” x 40”
Number Of Membranes
1 1 1 2
Dimensions W x H x D
(approximate inches)
22 x 32 x 12
22 x 52 x 12
Prefilter
(System ships with one 5 micron cartridge)
10”
Feed Water Connection
1/2” NPT
Product Water Connection (Tubing OD)
3/8”
Reject Water Connection (Tubing OD)
3/8”
Feed Water Required (Maximum)
2.4 gpm
Feed Water Pressure (Minimum
)
10 psi
Drain Required (Maximum)
2.4 gpm
Electrical Requirement
120 VAC 60 Hz 8 amps
Motor Horse Power
1/2
Shipping Weight
(estimated pounds)
50 50 60 70