INSTALLATION

Check the appliance is electrically safe and gas sound when you have finished.

29

ArtNo.280-0041 - Strain relief bracket 3-wire

ArtNo.280-0040 4 Wire Conduit Fitting

ArtNo.280-0039 Reducer Plate

ArtNo.280-0081 - 4 Wire

conduit terminal connection

lac

hite

ed

Green

Ground

ArtNo.280-0082 - 3-Wire conduit connection

train relie

device

hite

lac

ed

Ground strap

Ground

ArtNo.280-0042 Ground Strap

Fig.7-21

Fig.7-22

4-Wire Conduit Installation

Disconnect the supplied power cord from the terminal block

and ground post. Keep the terminal block parts; you will need

them. Remove the strain relief clamp from the power cord

and remove the power cord and strain relief clamp from the

mounting bracket (Fig.7-21).
The range is shipped with reducer plates to give a 1

1

/

8

’’

diameter opening for conduit connection. Find the reducer

plates (Fig.7-22) in the conversion kit and fix them to the

mounting bracket.
Attach a squeeze connector (not supplied with the range) to

your conduit. Insert the conduit through the reducer plates

on the mounting bracket. Allow enough slack to easily attach

the wires to the terminal block.
Note: Do not install the conduit without a squeeze connector.
Attach the wires to the ground post and terminal block

(Fig.7-23).
Note: Make sure the wires are completely inserted into the

terminals and secure connections are made.
Secure the squeeze connector in place in the bracket by

tightening the squeeze connector screws.
Replace the electrical connection cover.

Installing a 3-Wire Power Cord

Disconnect the supplied power cord from the terminal block

and ground post. Keep the terminal block parts; you will need

them. Remove the strain relief clamp from the power cord

and remove the power cord and strain relief clamp from the

mounting bracket. Discard the strain relief clamp.
Note: Do not install the power cord without a strain relief

– use the clamp supplied with the cord.
Install the new strain relief device to the mounting bracket by

removing the two clamping screws, feeding the two halves

(ears first) through the hole in the mounting bracket and

loosely replacing the screws. Insert the power cord through

the strain relief device but do not tighten the device yet

(Fig.7-24).
A ground strap is supplied in the conversion pack (Fig.7-25).
Attach the ground strap to the ground and center terminal of

the connector block (Fig.7-26).
The neutral or ground wire of the power cord must be

connected to the neutral terminal located in the center of the

connector block. The power leads must be connected to the

outside terminals.
Make sure the connections are tight. Now tighten the strain

relief device to clamp the power cord.
Refit the electrical connection cover.