Technical Specifications
18
Specifications:
Analog inputs (2 pairs, with 48 Volt phantom pow-
ering)
“Analogue Mic Gain”:“+10 dB”
“+20 dB”
Gain:
+10 dB
+20 dB
Maximum input level:
-5 dBU
-15 dBU
Maximum sound pressure level with CCM 2 S (omni-
directional) :
130 dB SPL 120 dB SPL
Analog outputs (3 pairs, balanced):
2 pairs of pass-through outputs, one pair of
processed signal outputs
Maximum analog output level: +4.5 dBU
Digital inputs (2 pairs):
Data format: AES/EBU
Digital outputs (3 pairs):
2 pairs of pass-through outputs, one pair of
processed signal outputs
Data format: AES/EBU
Synchronization/clock frequency:
with internal synchronization: 44,1/48/96 kHz
with external synchronization (via master inputs):
25 - 100 kHz
Maximum digital gain: 33 dB
Dynamic range:
A/D converter: 98 dB (peak)/CCIR
110 dB (RMS)/A-weighted
(108 dB (RMS)/unweighted)
D/A converter: 100 dB (peak)/CCIR
113 dB (RMS)/A-weighted
(110 dB (RMS)/unweighted)
Characteristic impedance of the cables which are
connected to the digital outputs: 110 Ohm
AC mains voltage: switchable 110-120 V / 220-240 V
Power consumption: 15 VA
Fuse: 230 V: 100 mAT; 110 V: 200 mAT
Dimensions (W
×H×D): 220 Ч 90 Ч 246 mm
(8,66
Ч 3,54 Ч 9,69 ”)
Weight: 2.7 kg (6 lbs)
Modes of operation
Since the DSP-4 KFM 360 offers both ana-
log and digital inputs and outputs, several
operating modes are possible:
Analog signals from microphones
Digital signals from a recorder
Digital input signals (e.g. from a record-
ing device)
Passed-through input signal (analog and
digital)
Processed signal (analog and digital)
Passed-through input signal (analog and
digital)
Processed signal (analog and digital)
Internal clock: 44.1, 48 or 96 kHz
External clock: via MASTER AES/EBU input (25 - 100 kHz)
The DSP-4KFM 360 will switch over to its digital inputs if a signal is presented at the
"Slave" AES/EBU input socket.
The unit connected to the MASTER AES/EBU socket will determine the clock fre-
quency (25 - 100 kHz).
Input