R4 series led light erdrebz3(xx) – SoundOff Signal R4 Series Recess Mount User Manual

Page 2

Advertising
background image

E36REBB3(XX) 11.06

R4 SERIES LED LIGHT

ERDREBZ3(xx)

FLASH PATTERNS for
R4 Series LED Light (fpm=flashes/minute)

Alternating Simultaneous X-Pattern Flashes /

#

Pattern Name

1 Light

2 Lights

2 Lights

4 Lights

Minute

1

Quint X

X

X

-

70

2 Warp

X

X

X

-

350

3 Inter-Cycle

Flash

X

X

-

-

4 Double

X

X

X

-

70

5 Quad

Flash

X

X

X

-

80

6 3

FPS

X

X

X

-

180

7

3 FPS

X

X

X

-

180

8

Q-Switch

X

X

-

-

9

Warp, Steady Burn

X

X

-

-

350

10

Quad, Steady Burn

X

X

-

-

80

11

E-Pattern Single Flash

X

X

X

-

230

12

E-Pattern Double Flash

X

X

X

-

125

13

E-Pattern Single Flash

X

X

X

-

230

14

E-Pattern Double Flash

X

X

X

-

155

15 X-Warp

-

-

-

X

350

16 X-Double

-

-

-

X

70

1LIGHT

Single Light Operation: Follow the ID Selection steps and set the light to ID#1 if it is not already. NOTE: Steady Burn is produced for
patterns 9 & 10 in Single Operation.

2 LIGHTS

ALTERNATING: To obtain Alternating patterns, follow the ID SELECTION steps and set one light to ID#1 and the other to ID#3. Then
proceed to the PATTERN SELECTION steps.

SIMULTANEOUS: To obtain Simultaneous patterns, follow the ID SELECTION steps and set both lights to ID#1. Then proceed to PATTERN
SELECTION steps.

4 LIGHTS


X-Pattern: To obtain X-patterns, follow the ID SELECTION steps and set one of the four lights to ID#1, one to ID#2, one to ID#3, and one to
ID#4. Then proceed to PATTERN SELECTION steps. NOTE: Be sure to mount each light in the correct placement based on ID#.

X-Pattern Sequence

ID#1 > ID#4 > ID#2 > ID#3

X-Pattern Light Head Placement

ID#4 ID#2

ID#3

ID#1

R4 Series Sync Configuration Instructions

1. Set ID#

a. Identify which pattern and sequence you want and look up ID#s on table.

b.

Connections

i. RED:

+12Vdc

ii. WHT: +12Vdc (Note: you will need to disconnect after power is applied)

iii.

BLK:

Ground

c. Apply power to unit

d. Without disconnecting power from unit, disconnect WHT wire

e. Momentarily connect WHT to Ground to change ID #

i. Identify ID# by number of sequential flashes

ii. Possible ID#s: 1 – 4

f. Disconnect power from unit to get out of ID mode.

2. Set Pattern

a. Reapply power to units.

b. Once all Light Head ID#s are configured, make sure all lights are flashing the same

pattern

c. Connect corresponding colored wires of all units together: RED to RED, etc.

d.

Change

Pattern

i. Momentarily connect WHT wires to Ground

ii. Observe pattern change on all lights connected

e. Insulate all wires by taping with electrical tape

3. Connect Master Switch for Application
a.

IMPORTANT! Ensure WHT Pattern/Sync Wires are tied together

Advertising