Viking Pump TSM275: AL-05 User Manual
Page 24
Page 24
7.2
Torque Settings
Item
Description
Position
1.02
Rotor Retainer
Rotor / Shaft
Quantity / Pump
Part No.
Torque – NM (ft lbs)
2
K13-2051-01M
24 (18)
2.01
Socket Head Cap Screw Front Cover / Pump Body
Quantity / Pump
Size
Torque – NM (ft lbs)
8
M8 x 20
39 (29)
4.01.13 Seal Locking Adapter
(Flush Only)
Pump Body / Seal
Housing
Quantity / Pump
Size
Torque – NM (ft lbs)
2
1/8” BSP
16 (12)
7.02
Socket Head Cap Screw Foot / Pump Body
Quantity / Pump
Size
Torque – NM (ft lbs)
3
M6 x 16
16 (12)
7.3
Lubricants.
The recommended lubricant for use in the Acculobe is lithium based, extreme
pressure grease intended for ‘sealed for life’ units. Suitable for operating
temperatures between –30°C and 120°C (-22°F to 266°F) and a base viscosity in the
region of 200 cSt at 40°C (104°F).
The unit is shipped with ‘Shell Retinax CS00’ type. Refer to manufacturers
recommended operating conditions concerning limitations, servicing and application.
In case of doubt, please consult the factory for details.
In any mounting attitude only 55 ml (1.86 US fl oz) is required to fill the gear cavity
and suitably lubricate the bearings. During the filling operation, lubricant should be
directed at the front bearings to ensure good circulation and coverage in this area.
Care should be taken not to overfill the gearbox.