Viking Pump TSM275: AL-05 User Manual

Page 24

Advertising
background image

Page 24

7.2

Torque Settings

Item

Description

Position

1.02

Rotor Retainer

Rotor / Shaft

Quantity / Pump

Part No.

Torque – NM (ft lbs)

2

K13-2051-01M

24 (18)

2.01

Socket Head Cap Screw Front Cover / Pump Body

Quantity / Pump

Size

Torque – NM (ft lbs)

8

M8 x 20

39 (29)

4.01.13 Seal Locking Adapter

(Flush Only)

Pump Body / Seal

Housing

Quantity / Pump

Size

Torque – NM (ft lbs)

2

1/8” BSP

16 (12)

7.02

Socket Head Cap Screw Foot / Pump Body

Quantity / Pump

Size

Torque – NM (ft lbs)

3

M6 x 16

16 (12)

7.3

Lubricants.

The recommended lubricant for use in the Acculobe is lithium based, extreme

pressure grease intended for ‘sealed for life’ units. Suitable for operating

temperatures between –30°C and 120°C (-22°F to 266°F) and a base viscosity in the

region of 200 cSt at 40°C (104°F).

The unit is shipped with ‘Shell Retinax CS00’ type. Refer to manufacturers

recommended operating conditions concerning limitations, servicing and application.

In case of doubt, please consult the factory for details.

In any mounting attitude only 55 ml (1.86 US fl oz) is required to fill the gear cavity

and suitably lubricate the bearings. During the filling operation, lubricant should be

directed at the front bearings to ensure good circulation and coverage in this area.

Care should be taken not to overfill the gearbox.

Advertising