Special information, Maintenance – Viking Pump TSM845: K-KK 825, 823, 827 User Manual

Page 3

Advertising
background image

SECTION TSM 845

ISSUE

F

PAGE 3 OF 14

Series 823, 825 and 827 pumps are designed for long,

trouble-free service life under a wide variety of application

conditions with a minimum of maintenance The points listed

below will help provide long service life

FIGURE 3

SPECIAL INFORMATION

CAUTION !

Rare earth magnets used in these

couplings have extremely strong

magnetic fields capable of changing the

performance or damaging items such as

the following:
Pacemakers

Metal Implants

Watches

Computers & discs

Credit Cards

Completely assembled magnetic

couplings will not affect items listed

above.
Altered performance or damage can

occur only when the coupling halves are

separated.
There are no known harmful effects of

these magnetic fields on the human

body.

MAINTENANCE

ROTATION: Viking Mag-Drive® pumps are designed to run

in the direction indicated on the nameplate only If rotation

must be reversed,

see “Pump Rotation” on page 10.

PRESSURE RELIEF VALVES:
1. Relief valves are mounted on the head of K and KK

size pumps Relief Valves are not available on jacketed

heads

2. If a Relief Valve is not furnished on the pump, some

means of over protection such as an in-line relief valve

should be provided Do not rely on magnets decoupling

for protection from over pressure This may result in

damage to magnets, pump or other equipment

3. Relief valve adjusting screw cap must always point

towards suction side of pump If pump rotation is

reversed, remove pressure relief valve and turn end for

end

(See “Pump Rotation” on page 10 for additional

steps required for proper operation)

See Figure 3.

4. Pressure relief valves cannot be used to control pump

flow or regulate discharge pressure

For additional information on pressure relief valves,

refer

to Technical Service Manual TSM000 and Engineering

Service Bulletin ESB-31.

DANGER !

Before opening any Viking pump liquid

chamber (pumping chamber, reservoir,

etc.) Be sure:
1. That any pressure in the chamber has

been completely vented through the

suction or discharge lines or other

appropriate openings or connections.

(See detailed procedure for venting

the pumps, pages 4, 5 and 6).

2. That the driving means (motor,

turbine, engine, etc.) has been

“locked out” or made otherwise non-

operational so that it cannot be

inadvertently started while work is

being done on the pump.

3. That you know what liquid the

pump has been handling and the

precautions necessary to safely

handle the liquid. Obtain a material

safety data sheet (MSDS) for the

liquid to be sure these precautions

are understood.

Failure to follow above listed

precautionary measures may result in

serious injury or death.

SUCTION

DISCHARGE

RELIEF VALVE ADJUSTING SCREW CAP

Advertising