Controlinx and the general purpose driver, General purpose driver/serial, Controlinx and the general purpose driver -40 – ClearOne NetStreams DigiLinX Dealer User Manual
Page 110

DigiLinX Dealer Setup Version 2.35.00
5-40
All specifications subject to change without notification. All rights reserved. Copyright © 2008 NetStreams
Main +1 512.977-9393 / fax +1 512.977.9398 / Toll Free Technical Support +1 866-353-3496
3600 W. Parmer Lane, Suite 100; Austin, TX 7872
Figure 5-33
Menu tab for the ControLinX hosting an Aprilaire
From the Menu tab, the thermostat is assigned to a room. This is how the user interface knows which
thermostat to display.
Table 5-23 provides information on the fields available for editing the Menu tab.
7.
Once all thermostats have been assigned, select Apply.
NOTE:
For information on the Input Sensor tab, see Input Sensor Tab for a ControLinX Contained in a MLA4000
on page 5-32.
ControLinX and the General Purpose Driver
You can control other devices or subsystems using one-way RS232 or IR. A ControLinX in an MLA4000
provides two choices for the general purpose driver: either serial (RS232) or IR. It also provides two sets of
screens to edit depending on which type of driver you choose.
The following subsections discuss the General Purpose Driver/Serial and the General Purpose Driver/IR.
General Purpose Driver/Serial
To edit ControLinX settings for the General Purpose Driver/Serial, complete the following steps:
1.
Connect the ControLinX with the external system using the 3.5mm to RS232 cable.
Table 5-23
Menu Tab
Tab
Selection Description
Menu
Thermostat Name
Choose from the dropdown list next to each item in the table
to assign it a thermostat.