ADS Environmental Services IntelliServe 2.8.1 950026A7 User Manual
Page 265
A-2
IntelliServe
User’s Guide
CONFIDENTIAL – Covered by ADS Terms of Use and Confidentiality Agreement in Contract
© 2010 ADS LLC. All Rights Reserved.
Flow Analysis)
incorrect downstream network configuration, or inaccurate data
from a monitor that may require further confirmations.
IntelliServe initiates an alarm when Qnet readings are negative
consecutively for one hour. Alarm conditions clear (return to
normal) when IntelliServe receives Qnet readings of zero or
higher consecutively for one hour.
Flow Loss (detected by
monitor)
This event indicates that the flow expected at the monitor is
below historically expected flow rates (QTHRESHOLD) or flow
depths (DTHRESHOLD) and could indicate that a spill has
occurred or that further confirmations are needed at the flow
monitor to verify accuracy of the data.
High Depth Level
Exceeded
This event indicates that the flow depth has exceeded the
specified threshold, reflecting warning conditions.
High High Depth Level
Exceeded
This event indicates that the flow depth has exceeded the
specified threshold, reflecting critical conditions. This event
commonly follows a High Depth Level Exceeded event.
Hydraulic Conditions
Change
This event indicates a significant change has occurred in the
hydraulic conditions present in the flow. The depth/velocity
relationship is no longer consistent with the expected data.
Import Data
This event indicates the administrator has imported data from
the local directory or network to the IntelliServe database.
Invalid Password
This event indicates that a user has entered a password that does
not correspond with the user name in the database when
attempting to log in.
Invalid User ID
This event indicates that a user has entered a user name that does
not exist in the database when attempting to log in.
Irregular Pressure Depth
This event represents a potential problem with the pressure
depth sensor indicated by pressure depth readings that do not
track with ultrasonic depth readings.
Irregular Pressure2 Depth This event represents a potential problem with the second
pressure depth sensor, as indicated by pressure depth readings
that do not track with ultrasonic depth readings.
Irregular Smart Depth
This event indicates a significant inconsistency in Smart Depth
readings based on historical data.
Irregular Smart Depth2
This event indicates a significant inconsistency in Smart Depth
readings on the second sensor based on historical data.
Irregular Ultrasonic
Sensor
This event indicates possible problems with the ultrasonic depth
sensor evidenced by an inconsistency between current readings
and historical data.