Dell PowerVault TL4000 User Manual
Page 194
Table 8-1. Main Error Codes (continued)
Error Code Description
User Action
C0
Network initialization failed
1.
Refer to “Isolating Web User
Interface Problems” on page 7-11.
2.
If the error recurs, contact
technical support.
C1
Telnet Interface initialization failed
C2
Webserver initialization failed
C6
Ping command did not reach target
C7
Cannot Upgrade from USB
Not supported
C8
Cannot Upgrade from FTP
1.
Retry the Firmware upgrade.
2.
If the error recurs, contact
technical support.
C9
Cannot Upgrade Robotic from Flash
D0
ROM error. ROM checksum incorrect
Refer to “Isolating a Library
Controller Card vs. Accessor
Enclosure Problem” on page 7-10.
Possible replacement CRUs:
v
Primary: Library Controller Card
v
Secondary: Library Enclosure
*D7 - Fatal System error can occur
because of an over-temperature
condition. Ensure that the
environment meets the
Environmental Specifications (refer to
“Environmental Specifications” on
page 1-14).
**If you receive a D8 error while your
library configuration is restored from
the OCP or Web UI, verify that your
file extension is .dbb. If the extension
is correct, your file was corrupted
during the save. Reconfigure, then
save your library configuration.
Note:
Configuration files that are
saved with one version of library
firmware might not be compatible
with other versions of firmware. It is
recommended to save a configuration
file each time the library firmware is
upgraded. Restore the library using a
configuration file that was saved
with the same version of firmware
that is currently installed in the
library.
D1
RAM error. Power on Self Test (POST) failed
D2
NVRAM (Non-Volatile Random Access Memory) error.
Read/Write operation to NVRAM failed
D3
CTC (Channel to Channel) Error. Timer unit failed during
POST.
D4
UART (Universal Asynchronous Receiver Transmitter) Error.
Frame overrun or Parity Error on serial Interface.
D5
Display Error
Communication to display failed
D6
Memory Error, Stack and heap overflow.
D7
Fatal system error*
D8
Database error**
D9
No SCSI IC detected
DA
While the Library Verify Test is running, the bar code reader
reads different bar code data for the same customer-supplied
scratch cartridge label.
1.
Check the barcode label on the
scratch cartridge and run the
Library Verify test again.
2.
If the error recurs, contact
technical support.
DB
Warning Event! See Table 8-3 on page 8-11
DC
I²C Bus Failure
1.
Retry the operation.
2.
After several occurrences, contact
technical support.
DD
Warning Event! See Table 8-3 on page 8-11
8-4
Dell PowerVault TL2000 Tape Library and TL4000 Tape Library User's Guide