Troubleshooting: Your Array

Equip yourself with antistatic protection and a replacement small form-factor

pluggable (SFP) transceiver before replacing an SFP transceiver in the RAID

controller module. Also, see the initial setup information for the enclosure to

verify LED definitions.

1 If possible, use the storage management software to create, save, and print

a new storage array profile.

2 If the Recovery Guru directed you to replace a failed RAID controller module,

go to step 3, else run the Recovery Guru to identify the failed component.

3 Unpack the new SFP transceiver.

NOTE:

Ensure that the SFP transceiver is replaced by the same type.

NOTE:

Set the new SFP transceiver on a dry, level surface near the RAID

controller module, the RAID controller module enclosure, or the

expansion enclosure.

NOTE:

Save all the packing materials in case you need to return the

SFP transceiver.

4 To locate a failed SFP transceiver, view the FCIN (host channel) speed

LEDs on the front of the RAID controller modules. If an SFP transceiver

has failed, both FCIN speed LEDs for a particular port are off.
• If both FCIN speed LEDs are off for a particular port with a known

good cable, the SFP transceiver must be replaced. Go to step 6.

• If at least one FCIN speed LED is on for a particular port, the SFP

transceiver is functional. The FCIN speed LEDs indicate a channel

speed of 2 Gbps, 4 Gbps, or 8 Gbps (see "Host Channel LED

Link/Rate Indications" on page 36). Ensure that the speed indicated

by the LEDs is what is expected.

WARNING:

Data processing environments can contain equipment transmitting

on system links with laser modules that operate at greater than Class 1 power
levels. Never look into the end of an optical fiber cable or open receptacle.

CAUTION:

To prevent degraded performance, do not twist, fold, pinch, or step on

fiber optic cables. Do not bend the fiber optic cables tighter than a 5 cm (2") radius.

5 If present, disconnect the fiber optic cable from the failed SFP transceiver.
6 Remove the failed SFP transceiver from the interface port.

book.book Page 296 Tuesday, June 18, 2013 3:03 PM