Eden DC-210XLT Metro User Manual

Page 7

Advertising
background image

7

Mains On/Off Switch – This switch turns the system power ON or OFF.
The switch illuminates to indicate the presence of AC power present in the
chassis. This switch is prior to the fuse. The light in the switch may flicker
depending on local voltage conditions. This is normal and nothing to be
concerned about.

NOTE: The Mains Switch will illuminate even if the fuse is blown.
However, the DC Indicators will not illuminate if the fuse is blown.

REAR PANEL FEATURES

Amplifier Power Rating:

RMS output per channel:
300 Watts @ 8 Ohms
550 Watts @ 4 Ohms
750 Watts @ 2 Ohms

All modes of operation have +3dB of headroom. This means that the peak
power is twice that of RMS.

Combination Power Cord Jack and Fuse Holder – The removable power
cord is attached here. To access the fuse holder, pull the holder out of the top
of the power receptacle. Your unit was shipped with a spare fuse inserted in
the fuse carrier. USE ONLY THE SAME SIZE AND TYPE FOR
REPLACMENT. Using a fuse with a different rating than specified is a
VERY BAD THING and can cause damage to your amplifier. All
models are factory configured for 100/120 or 230/240, depending on country
in which sold, and must be adapted by a service tech for any voltage change.

Fuse Requirements:

USA @ 120 Volts /60 HZ – 8 Amps, 5 x 20 mm GMC/T/slow blow
Europe @ 240 Volts/50 Hz - 4 Amps, 5 x 20 mm GMC/T/slow blow

IMPORTANT NOTE: Always use slow blow or time delay type fuses.
Do not use fast blow fuses.

VERY IMPORTANT NOTE: In order to adapt your amplifier to
operate properly at a different voltage, it will require minor
modifications. These modifications should be made by a QUALIFIED
technician. Contact your local distributor for further information.

Advertising