EFCO 8800 Series Assembly Instructions Vol.5 User Manual
Page 14
EFCO 2009
Page 14
Series 8700 / 8800 Unitized Curtain Wall Assembly Instructions - Volume 5
2. Using an approved solvent or cleaner, clean the sealant contact surfaces of the jamb adapters and mullions of all oils and other contaminants.
3. Apply sealant to the contact surfaces at the intersection of the concealed vent horizontals and the vertical mullions where the jamb adapter abuts into the
horizontals (4 locations). See Figures 12 and 13 on page 15.
4. Apply sealant to each end of the concealed vent jamb adapters. See Figures 14 and 15 on page 15.
Section 19 - Frame Assembly - Vent at Stack Sill
Figure 11
17L5 Concealed Vent
Jamb Adapter
17L5 Concealed Vent
Jamb Adapter
Apply sealant at the intersection of the
concealed vent horizontals and the verticals
where the ends of the jamb adapter will abut.
(See Figures 12 and 13 on page 16).
Apply sealant to each end of
the jamb adapters. (See
Figures 14 and 15 on page 16).
Concealed Vent
opening
HEAD
SILL