Final steps - all systems – Environmental Water Systems CWL CHLORAMINE 1865 User Manual

Page 15

Advertising
background image

15

22.

Check the drain water is clear of any filtration media dust and/or fines. A quick repeat of the the flushing procedure

is recommended.

Start a backwash again (Page 13, Step # 19) and once water flows under full pressure through the drain line check

for any dust and/or fines. Allow water to run through the drain line for at least 60 seconds.

Once the drain water appears clear, force the control to advance to the next cycle step immediately by pressing and

releasing the Extra Cycle Button. The Parameter Display flashes “RR” and the Data Display reads “----”.

You will hear the valve engage again and it will take about 11/2 minutes (90 seconds) to engage the cycle. Once

water flows under full pressure through the drain line check for any dust and/or fines. Allow water to run through the

drain line for at least 60 seconds.

Once the water runs clear, force the control to advance to the next cycle step immediately by pressing and releasing

the Extra Cycle Button. The valve will engage again and it will take about 30 seconds for the valve to return to the

in service position and the display will show the In Service Icon and your Time of Day.

23.

Slowly open the Outlet Side of the Bypass Valve

Final Steps - All Systems

LAST STEPS BEFORE LEAVING THE SYSTEM

NOTE:

Holes appear on the front and back

of Bypass Valve when open.

(see illustration to the right)

24.

System is ready for use.

To ready home for filtered water, open as many hot and cold faucets throughout the home as possible. Remove

the aerators or any restriction at the end of the faucets. Remember to include tubs and dispose of any ice previ-

ously made. Run water throughout home for 5 minutes.

NOTE: If water appears cloudy, allow to run for several more minutes until all air is expelled or until clear.

NOTE:

If home is a year or more old, it is highly recommended that all water heaters or tankless on-demand heaters be

flushed and that all dishwashers, washers and any other water appliances be cleaned of any existing residue.

Please review Page 7 “Instructions Before Using” for existing plumbing and pre-existing conditions that will effect

the performance of this system.

WARNING:

Failure to follow these procedures can result in debris in the system, the system’s valve, the home and/or

filtration media being expelled causing immediate, short and long term issues with the system’s valve,

into the home pipes and the fixtures or appliances within the home.

Outlet Valve

Open

Inlet Valve

Open

Illustration of Bypass Valve

Open Outlet and Inlet

Top View