Valve controls - all systems – Environmental Water Systems CWL CHLORAMINE 1865 User Manual

Page 3

Advertising
background image

3

SCHEMATIC: ALL SYSTEMS - Valve, Bypass, Adaptors and Valve Controls

BYPASSED

IN SERVICE

Supplied Bypass Valve - All Systems

Top View

Outlet Valve

Closed

Outlet Valve

Open

Inlet Valve

Closed

Inlet Valve

Open

INLET

Incoming

Water

Supply

OUTLET

Filtered

Water to

Home

INLET

Incoming

Water

Supply

OUTLET

NOTE:

Inlet

and

Outlet

Valves

are

closed

and

in

the

bypass

position

when

the

holes

appear

at

the

top

and

bottom

as

shown

to the right

No Flow Into System

Flow Into System

to be Filtered

Flow of Filtered

Water from System

NOTE:

Inlet
and
Outlet

Valves

are
open

and
in

the
service

posi
-

tion
when

the
holes

appear

at

the
sides

(or
do

not
appear

on

top)

as shown to the left

Valve Controls - All Systems

What is normally seen on the display:

Current Time of Day in Data Display

PM Indicator (if applicable)

Data Display will alternate (every 10

seconds) between Time of Day to another

number and then back to the Time of Day

- this is normal and tells the user the next

time the system will backwash counting

down each day from 6 (factory pre-set) until

backwash

In Service Icon

During Installation when instructed:

Use the Up and/or Down Button to set

the Time of Day

Use the Extra Cycle Button to flush the

system. The Parameter Display will appear

and indicate the cycle engaged (“BW” or

“RR”) during backwashing and the Data

Display will indicate time remaining during

a cycle

Contact EWS Customer Service if you see

an Error Icon or have wandered into a Pro-

gramming Mode that you do not understand.

valve

controls

1” MNPT

drain fitting with

grey clip

7’ electric cord &

24v transformer

(not shown)

model number

and labeling

NOTE: a total of seven (7) red connection clips are used

**

A (1) - clip, top cap assembly, B (2) - clips, valve to bypass, C (2) - clips, bypass to adaptors, D (2) - clips, bypass assembly

C

bypass to adaptors

clip connections

B

valve to bypass

clip connections

A

B

C

C

B

D

D

valve body

built-in bypass

1”, 1 1/4” & 1 1/2”

MNPT adaptors provided

ALL SYSTEMS: Illustration of Complete Valve Assembly, Bypass and Provided Adaptors: 18” Overall Length Front to Back

3”

on center

**WARNING:

Removal of any red clip while unit is under pressure will result in water damage and damage to valve. See other cautions within this manual.

removable

valve

cover

Parameter

Display

Data

Display

PM

Indicator

In Service

Icon

Error

Information

Icon

Programming Icon

Extra Cycle

Button

Up

Button

Down

Button

Advertising