Timer operation

press the TIMER ON button can set the auto-on
time of the unit. And press the TIMER OFF button
can set the auto-off time of the unit.

1. Press the TIMER ON button. The remote
controller shows TIMER ON, the last Auto-on
setting time and the signal "HOUR" will be shown
on the LCD display area. Now it is ready to reset
the Auto-on time to START the operation.
2. Push the TIMER ON button again to set desired
Auto-on time. Each time you press the button,
the time increases in 30 minutes increments, up
to 10 hours, then at 1 hour increments up to 24
hours.
3. After setting the TIMER ON ,there will be a one-
half second delay before the remote controller
transmits the signal to the heat pump. Then,
after approximately another 2 seconds, the
signal "HOUR" will disappear and the set temper-
ature will re-appear on the LCD display window.

To set the Auto-on time.

To set the Auto-off time.

1. Press the TIMER OFF button. The remote
controller shows TIMER OFF, the last Auto-off
setting time and the signal "HOUR" will be shown
on the LCD display area. Now it is ready to
reset the Auto-off time to START the operation.
2. Push the TIMER OFF button again to set desired
Auto-off time. Each time you press the button,
the time increases in 30 minutes increments, up
to 10 hours, then at 1 hour increments up to 24
hours.
3. After setting the TIMER OFF ,there will be a one-
half second delay before the remote controller
transmits the signal to the heat pump. Then,
after approximately another 2 seconds, the
signal "HOUR" will disappear and the set temper-
ature will re-appear on the LCD display window.

The effective operation time set by the remote controller for the timer
function is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0,
3.5, 4.0, 4.5, 5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13,
14, 15,16,17, 18, 19, 20, 21, 22, 23 and 24.

IMPORTANT

Example of Timer setting

Start

Off

6 hours later

(Auto-on Operation)
The TIMER ON feature is useful when you want
the unit to turn on automatically before say when
you return home. The heat pump will automa-
tically start operating at the set time.

To start the heat pump in 6 hours.
1. Press the TIMER ON button, the last setting of
starting operation time and the signal "HOUR" will
show on the display area.
2. Press the TIMER ON button to display "6.0" on
the TIMER ON display of the remote controller.
3. Wait for 3 seconds and the TIMER ON indicator
stops flashing and this function is activated. The
digital display area will show the tempera ture
again.

TIMER ON

Example:

Set

MODE

FAN SPEED

SWING V

SLEEP

TIMER ON

TIMER OFF

CLOCK

RESET LOCK

AUTO

COOL

DRY

HEAT

FAN

TEMP.

SET

CLOCK

TIMER

HOUR

ON

OFF

M

TIMER

HOUR

ON

SWING H

SELF CLEAN

TURBO

LED

I FEEL

Advertising