CLS-420 Installation Manual
3.2
Cable Connections
The 420 indicator provides two cord grips and two MIL-C connectors for cabling into the indicator: The free cord
grip comes with a plug installed to prevent moisture from entering the enclosure.
Figure
3-3 shows the assignments for the 420 cord grips.
Front of
indicator
Setup switch
access screw
MIL-C power
cable connecting to
forklift battery
RS-232 if used
(plugged)
Wireless
scale
indicator
transiever
Wired scale
connection
(not wired for the
wireless version)
Backplate
Bottom View
Figure 3-3. 420 Rear of Indicator
3.3
Supplying Power to the Indicator From the Forklift Battery
CAUTION
The indicator power source will be connected directly to the battery of the forklift. Most typical is 12 volts
for propane, gas and diesel forklifts. However, some diesel forklifts are 24 volts.
12 and 48 volt systems must have a negative ground so ensure the forklift has a negative ground
electrical system. The CLS series cargo lift scale will not operate on a positive ground forklift.
Refer to the forklift user’s manual for further verify grounding requirements.
The indicator draws its power from the forklift battery. After the indicator is mounted, run the power cable along
the forklift chassis down to the forklift battery.
Run power cable along
chassis to the forklift
scale battery
Figure 3-4. Run Power Cable to the Forklift Battery
Note
DO NOT plug in the power connector into the bottom of the indicator until power hookup is completed.