Vintage Cellars Transtherm Double Castel Glass Door Black User Manual

Page 11

Advertising
background image

P 11

GB

Please note:
- The service temperature control is operated manually and is turned on and off by
pressing the switch on the left-hand side (see diagram).
- When in “on” mode, the red light located on the switch is lit.
- When in “off” mode, the light is off.
- The temperature of this compartment is not displayed.
- When the button is put in “on” mode: the setting is 18°C, it is activated at 15°C and
switches off when the temperature reaches 18°C.
- Once the wine has reached serving temperature, do not forget to remove your bottles
and put the switch in the “off” position: If you forget to turn off the service tempera-
ture button the temperature will be regulated between 15°C min. and 18°C max.
- The lighting function is manually controlled (“Light” On/Off switch).
If you are no longer using it, remember to switch off the lighting.

Pressing! for

5 seconds

allows you

to access:

“ST” allows you to set the wine
maturing temperature (for 1 and 3
temperature models) or the upper
section (for multi-temperature
models).

Pressing Set: Allows you to read
the set temperature of the “ST”
setting.
Pressing Set twice: Allows you to
return to the “ST” display

Allows the different parameters to be displayed.

Allows the different parameters to be displayed.

Pressing Set: Allows you to read
the “H4” setting value:
H4=O means that the warning
alarm is active.
H4=1 means that the warning
alarm is disabled

Pressing Set twice: Allows you to
return to the “

H4

” display.

“H4” Allows you to activate or disa-
ble the warning alarm, if a malfunc-
tion occurs.

« ST »

« H4 »

Advertising