General information assembling vent pipes, Dvrt41 direct vent gas fireplace, Flex vent pipes – Vermont Casting DVRT41 User Manual

Page 12

Advertising
background image

12

DVRT41 Direct Vent Gas Fireplace

10006740

Outside Corner

Inside Corner

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.

A =
Combustible
6"(152mm)

Noncombustible
2"(50mm)

B =
Combustible
6"(152mm)

Noncombustible
2"(50mm)

A

Balcony -
with no side wall

G =
Combustible &
Noncombustible
12"(305mm)

G

Balcony -
with perpendicular side wall

H = 24"(610mm)

J = 20"(508mm)

H

J

B

Recessed Location

C = Maximum depth of 48"
(1219mm) for recessed
location.

D = Minimum width for back wall
of a recessed location.
Combustible 38"(965mm)
Noncombustible 24"(610mm)

E = Clearance from corner in
recessed location.
Combustible 6"(152mm)
Noncombustible 2"(50mm)

C

D

C

E

V

V

Combustible &
Noncombustible

V

V

V

584-15

Fig. 15 Termination clearances.

General Information Assembling Vent Pipes

Canadian Installations

The venting system must be installed in accordance
with the current CSA-B149.1 installation code.

USA Installations

The venting system must conform to local codes and/or
the current National Fuel Code ANSI Z223.1/NFPA 54.

Only venting components manufactured by CFM
Corporation may be used in Direct Vent systems.

Flex Vent Pipes

Before joining the flex vent pipe to the unit, apply a
bead of high temperature sealant* (provided) to the 4”
pipe exiting the fireplace. Secure flex vent piep in place
with a hose clamp (provided).

*Be sure the flex pipe overlaps at least 1” (25mm) onto
the collars of the fireplace and termination. If the
termination has an internal bead, be sure to overlap
and secure 1” (25mm) past the bead.

* Be sure the venint is actually crushed before pro-
ceeding. Apply a tug to be sure the vent will not slip off
the collars.

Repeat process with 7” flex vent pipe. The same
procedure must be performed on the vent side.

Apply High Tempera-
ture Sealant

Hose Clamp

FP1471

Fig. 16 Apply high temperature sealant to 4” and 7” pipes.