Maintenance mode displays 6-3, 3 maintenance page 3, 4 maintenance page 4 – BendixKing FPI 3501B System FPD 500 User Manual
Page 55: Figure 6.4-1 maintenance page 4, Figure 6.3-1 maintenance page 3
FPD 500 FLAT PANEL DISPLAY SYSTEM
6.3 MAINTENANCE PAGE 3
The following is the definition of
the states for the page:
Parameter
States
LAMP
REPLACE/
PASS/FAIL
IP, GP,ETC.
PASS/FAIL
6.4 MAINTENANCE PAGE 4
The following is the definition of
the states for the page:
Parameter
States
PUSHBUTTON
0/1
NOTE: Remember, if you are
testing the buttons, that pressing
the R button will advance to the
next page, and pressing the N
button will exit the maintenance
mode.
Maintenance Mode Displays
6-3
Rev. 0
Jan/97
A
N
M
R
I
DIM
TEST
BRT
DU BEZEL STATUS
PG 04
BRT PUSHBUTTON
0
DIM PUSHBUTTON
0
N PUSHBUTTON
0
M PUSHBUTTON
0
R PUSHBUTTON
0
I PUSHBUTTON
0
TEST PUSHBUTTON
0
Figure 6.4-1
Maintenance Page 4
N
M
R
I
DIM
TEST
BRT
DU STATUS
PG 03
LAMP
PASS
IP
PASS
GP
PASS
POWER SUPPLY
PASS
DIMMER/LCD
PASS
I/O #1
PASS
I/O #2
PASS
BEZEL
PASS
Figure 6.3-1
Maintenance Page 3