Removal and inspection of trunnion arm – Cub Cadet P Series User Manual

Page 127

Advertising
background image

122

PW Series

Refer to Figure 16.

Disassembly
1. Remove trunnion seal retainer and seal (12).

2. Remove the slot guide (14).

3. Remove the trunnion arm (13).

Inspection
1. Inspect the trunnion arm (13) for wear or damage.

Replace the trunnion arm if necessary.

Assembly
1. Install the trunnion arm (13) into the housing

(15) bore. Rotate the trunnion arm to verify free

movement.

2. Install a new seal and seal retainer.

3. Install the slot guide (14).

4. To completely reassemble the pump, refer to

the assembly steps on pages 111-122. Begin

with the trunnion arm assembly steps listed on

page 122 and complete the assembly steps in

reverse order working towards the front of the

manual.

REMOVAL AND INSPECTION OF

TRUNNION ARM

NOTE: Upon removal, it is recommended

that all seals, O-rings, and gaskets be re-

placed. During installation, lightly lubri-

cate all seals, O-rings and gaskets with

clean petroleum jelly prior to assembly.

Also protect the inner diameter of seals

by covering the shaft with plastic wrap.

Remove the plastic wrap after the seal

is installed.

Figure 16. PW Pump Trunnion Arm

15

12

13

14

Advertising