Cub Cadet P Series User Manual

Page 51

Advertising
background image

46

PG / PE Series

Refer to Figure 11a and 11b.

disassembly
1. Using a 10 mm wrench, loosen the end cap bolts

(4) evenly.

2. Keeping the end cap (2) held in place, remove

the four end cap bolts (4).

3. Slowly remove the end cap (2).

4. Remove the valve plate (31).

NOTE: Not applicable in PE-series pumps.

5. Remove housing alignment pins (3).

6. Remove housing gasket (5).

Inspection
1. Inspect the end cap body (2) for damage,

nicks or unusual wear patterns. Replace if

necessary.

2. Inspect the running surface (side that contacts

the cylinder block) of the valve plate (31). The

running surface may show evidence of minor

abrasive rings, this is normal.

NOTE: Grooving in the valve plate and or

end cap, made evident when the surface is

checked by dragging a fingernail across it,

would be cause for replacement of the valve

plate.

3. Inspect and replace alignment pins (3) if bent

or distorted.

4. Replace the housing gasket (5) with a new

gasket before reassembly.

Assembly
1. Install housing gasket (5) into housing gasket

seat of housing (1).

2. Install alignment pins (3) into housing (1).

3. Lubricate the valve plate prior to installation.

Install valve plate (31) so the stamped letters

“UP” on the valve plate are facing up toward

the end cap.

NOTE: Not applicable in PE-series pumps.

4. Lubricate the end cap (2) face prior to

installation in PE-series pumps.

5. Install end cap (2). Before installing the four

end cap bolts (4), push down on the end cap

(2) verifying alignment and insuring that the

cylinder block pistons spring back and forth.

Install end cap bolts (4). Tighten, reference

Table 2, page 38 torque values.

REMOVAL, INSPECTION ANd

ASSEMBLY OF THE ENd CAP ANd

VALVE PLATE

Figure 11a. PG Pump End Cap

4

2

5

31

3

1

3

1

5

4

2

PG Series Pumps (With Valve Plate)

PE Series Pumps (No Valve Plate)

Figure 11b. PE Pump End Cap

Advertising