Inovonics EN4232MR User Manual
Page 6
© Inovonics, 2011 - www.inovonics.com
6
14 ADT Focus 200 Plus / Focus Cadet Control Panel Wiring and Programming Information
14.1 Typical EN4232MR Receiver Connection to ADT Focus 200 Plus / Focus Cadet Control Panel
EN4232MR Function EN4232MR
Terminal
Panel Terminal
Keypad Text
Power in (12V DC)
Vs
(19) + Aux Power
n/a
Ground
GND
(20) - Aux Power
n/a
Alarm 1
NC (1)
(25) Point 1
(user text)
(Follower)
C (1)
(26) Common
NO (1)
Alarm 2
NC (2)
(27) Point 2
(user text)
(Follower)
C (2)
(28) Common
NO (2)
Repeater AC Loss
NC (3)
(29) Point 3
RF Repeater AC
(Follower)
C (3)
(30) Common
NO (3)
RF Pt Low Battery
NC (4)
(32) Point 4
RF Pt Low Batt
(Latching)
C (4)
(31) Common
NO (4)
RF Pt Tamper
NC (5)
RF Pt Trouble
(Latching)
C (5)
(34) Common
NO (5)*
(33) Point 5
RF Pt Inactive
NC(6)
(35) Point 6
RF Pt Inactive
(Follower)
C (6)
(34) Common
NO (6)
Power Loss
POWER LOSS
(36) Point 7
RF Recvr Power
(Follower)
(37) n/a
Receiver Tamper
NO (TAMP) *
n/a
(Follower)
C (TAMP) *
n/a
RF Jam
NC (JAM)
(38) Point 8
RF System Jammed
(Follower)
C (JAM)
(37) Common
* Point 5 is normally open to allow RF Pt Tamper and Receiver Tamper on one loop.
The 2K-ohm end-of-line resistor is connected across TAMP NO (normally open) and TAMP C (common)
Wire from TAMP NO to 5 NO.