Lk-g-m-no4-e, 4 input/output terminals – KEYENCE LK-G Series User Manual
Page 126

4-14
4
LK-G-M-NO4-E
4 Input/Output Terminals
Peak hold/bottom/peak-to-peak hold/average hold/sample hold (trigger 1)
• The minimum input time (T1), input response time (T2), RESET time (T4), and program No. change
time (T7) vary depending on the settings.
• The STROBE time (T3) can be changed.
• Auto-zero is canceled when the ZERO input is turned on for two seconds or more.
• The internal measurement value of the RESET input is determined after the RESET time (T4) has
elapsed.
Refer to page 4-17.
Refer to page 3-43.
Comparator output
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Binary output
STROBE output
TIMING input
RESET/
ZERO input
P1 to P3 inputs
At Trigger 2
At Trigger 1
0.2ms
T3
Min
Min
Min T1
MinT1
MinT1
T1
MaxT2
MaxT2
MaxT2
Max
Sampling
peirod
Sampling
peirod
Sampling
peirod
Sampling
peirod
T4
T4
T4
Min T1
T1
T7