Temporary Suspension of Safety Function

2-43

Fu
nct
ion
s and

Feat

ures

2

SL-V-M-NO2-E

Changing of the condition for termination of muting (maximum muting period)

(1) Follow the procedure under "Entering the password".

"Entering the password" (page 2-39)

(2) This setting depends on the state of the override input (red/black wire on the receiver).

ON: The condition for termination of muting (maximum muting period of approx. 5 minutes) is deac-
tivated, which means that no defined maximum muting period is active. (the interlock indicator on

the receiver blinks.)
OFF: The condition for termination of muting (maximum muting period of approx. 5 minutes) is acti-
vated, which means the default period is active. (the interlock indicator on the receiver does not

light.)

(3) Turn ON the muting input 1.
(4) Turn ON the muting input 2, and then turn OFF the muting input 2. You must repeat this action three

times. The LED 1 and LED 2 on the bar LED on the receiver light in green.

(5) Turn OFF the muting input 1.
(6) Turn ON the muting input 2.

(7) Turn ON the muting input 1, and then turn OFF the muting input 1. You must repeat this action four

times. The bar LED 3 on the receiver lights in red.

(8) Turn OFF the muting input 2.

(9) If these procedures are performed correctly, the LED 1 and LED 2 on the bar LED on the receiver

light in green. Afterwards, the center indicator on the receiver lights in red and then lights in green
again approximately one second later. This indicates that the settings are completed.

(10) Turn OFF the power to the SL-V, and then the interlock mode selection input (pink wire from the

transmitter) must be wired.

"Interlock Function" (page 2-7)

(11) The condition for initiation of muting (time period between muting input 1 and 2) is changed when

the power to the SL-V is turned ON. The SL-V keeps this condition even if the power to the SL-V is

turned OFF.

When another condition for muting, regardless of initiation or termination, is also changed in addition to the
change of the above-mentioned condition, you can continue the procedure for another condition following
the step (9).
On the other hand, when the change of the above-mentioned condition follows the change of another con-
dition for muting, regardless of initiation or termination, you can waive the step (1).

Ex.: Time chart when the maximum muting period (default) is deactivated

Reference

Override input

From here on, the override
input can be either on or off

ON

OFF

Muting input 1

ON

OFF

Muting input 2

ON

OFF

ON

OFF

SL-V

P

erf
or

m "Enter

ing the pass

w

ord"

B

2 s or more

B

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A: 20 ms or more, B: 40 ms or more

(2)

(3)

(4)

(5)

(7)

(10)

(1)

(6)

(8)

Cable

Self-diagnosis

Series Connection

Interlock

AUX

EDM

Wait

State Information

Alert

Clear/Blocked

Suspension

Fixed

Reduced

Monitoring