TYPICAL SPECIFICATIONS
Supply
an
ICE
(US),
Inc.
direct
fired
make-‐up
unit
designed
for
(indoor)
(outdoor)
installation.
The
capacity
and
configuration
shall
be
as
detailed
on
the
drawings.
The
unit
shall
be
CGA
and
ETL
certified
and
listed
to
be
in
compliance
with
the
current
ANSI
Z83.18
standard.
The
line
burner,
gas
train
and
controls
are
to
be
in
accordance
with
(ANSI)
(FM)
(IRI)
(FM
and
IRI)
requirements.
Both
burner
and
blower
shall
be
compensated
for
altitude
of
operation.
The
unit
is
to
be
completely
factory
test
fired
to
verify
proper
operation.
The
unit
capacity
is
to
be
validated
with
an
instantaneous
flow
meter.
A
complete
electrical
circuit
analysis
is
to
be
conducted
and
all
systems
operated
and
measured.
A
combustion
analyzer
is
to
be
employed
while
unit
is
operating
at
full
capacity
to
verify
combustion
emissions.
Burner
combustion
must
be
clean
and
odorless
and
no
aliphatic
aldahydes
are
to
be
detectable.
Combustion
efficiency
must
limit
the
products
of
combustion
to
a
maximum
of
5
ppm
carbon
monoxide
and
0.5
ppm
nitrogen
dioxide.
UNIT
CASING
Unit
construction
is
to
be
of
industrial
quality
heavy
gauge
bonderized
steel.
The
unit
design
shall
incorporate
a
full
base
pan
supported
by
an
integral
welded
channel
iron
base.
Bases
are
to
be
of
industrial
welded
structural
iron
integrity,
formed
sheet
metal
bases
are
unacceptable.
All
structural
iron
base
supports
are
to
be
treated
with
an
industrial
epoxy
primer
enriched
with
a
rust
inhibitor.
To
ensure
the
casings
are
airtight
and
weatherproof,
all
panels
are
to
be
caulked
during
assembly.
All
casings
are
to
be
hand
fitted
and
secured
with
gasketed
self-‐tapping
tek
screws.
Roof
casing
are
to
feature
three-‐break
standing
seam
panel
design.
Roof
casings
are
to
be
sloped
on
outdoor
units
to
prevent
standing
water.
Sloped
roofs
are
to
be
¼
in.
per
foot
and
feature
full
drain
troughs.
Entire
unit
casing
and
accessories
are
to
be
insulated
with
fiberglass
insulation
with
hard
neoprene
facing.
(1
or
2
in.
thick
1-‐1/2#
or
2#
density)
insulation
is
to
be
secured
with
industrial
glue
and
welded
pin
spots.
Insulation
is
to
be
certified
to
fire
and
flamespread
ratings
as
outlined
by
the
ANSI
code.
The
entire
floor
of
the
unit
is
to
feature
a
steel
liner
sandwiching
the
insulation.
Units
are
to
be
equipped
with
access
doors
to
all
serviceable
components.
Access
doors
are
to
have
full-‐length
stainless
steel
piano
hinges.
All
access
doors
are
to
be
equipped
with
an
insulation
liner,
positive
seal
latches
and
gasketing
.
Access
doors
are
to
open
outward
on
negative
pressure
sections
and
inward
on
positive
pressure
sections.
Access
doors
to
feature
6
in.
handles
with
locking
roller
mechanism
for
ease
of
latching.
All
outdoor
unit
access
doors
are
to
be
equipped
with
drain
troughs.
Units
are
to
be
finished
with
an
industrial
grade
chain
stop
alkyd
enamel
paint.
The
medium
grey
finish
coat
is
to
be
a
mimum
of
3
mils
thick
and
provide
100%
coverage.