IC Realtime 1.3 Megapixel 18X PTZ Network Camera (ICIPMP1801S) User Manual

Page 26

Advertising
background image

26

• BACK: Go back to the previous menu.
• EXIT: Log out the system menu.

Menu Password
Move the cursor to the MENU PASSWORD and the click the confirm button to go to the fourth menu.

• PASSWORD: It is to set the speed dome menu password. Please use the left/right button to set.
• SETTING: Click the confirm button to go to the password setup interface. Please use the left/right

button to set the value and then click the confirm button to confirm current option. Move the cursor to
the SAVE button and then click the confirm button to save current setup. Click the BACK button to
go to the previous menu.

• BACK: Go back to the previous menu.
• EXIT: Log out the system menu.

If you have forgot your password. After three times of login failure, system may pop up an 8-digit

internal code. Please contact our technical engineer for help.

2.4.5 Alarm Setup

Move the cursor to highlight ALARM SETTING button and then click confirm button.
z

ALARM NO: Here is to set alarm input. Alarm input value ranges from 1 to 7. Please use the left/right

button on the keyboard or in the speed dome terminal menu to set.

z

ACTION: Action on alarm function. It includes NONE/PRESET/AUTO SCAN/TOURING functions.

Please use the left/right button on the keyboard or in the speed dome terminal menu to set.

z

CONTACT

:You can set system activation operation once alarm occurred. There are two alarm signal

mode: normal open (N/O) and normal closed (N/C). Please use the left/right button on the keyboard or
in the speed dome terminal menu to set.

z

PRESET

NO.

:Please use the left/right button on the keyboard or in the speed dome terminal menu to

set. The camera will turn to the specified preset to monitor after alarm occurs.

z

AUTO

SCAN

:Please use the left/right button on the keyboard or in the speed dome terminal menu to

set. The camera will begin auto scan after alarm occurs.

PASSWORD :

SETTING :

BACK

EXIT

PASSWORD:

1

2 3 4 5

6

7 8 9 0

→ SAVE BACK

ALARM NO. : 01

ACTION : NONE

CONTACT : N/O

PRESET : 001

AUTO SCAN : 001

CRUISE : 001

RELAY OUT : OFF(OFF/1→5S/2→5S/1&2→

5S)

RESET DELAY : 3S

SAVE

BACK

EXIT

Advertising