4 faq, 1 daily maintenance, 2 problems and solutions – IC Realtime 1.3 Megapixel 18X PTZ Network Camera (ICIPMP1801S) User Manual

Page 30

Advertising
background image

30

4 FAQ

4.1 Daily Maintenance

Please clean dome cover regularly to get vivid image.
Handle the cover with care. Use water to wash. Don’t use cloth to clean.
Use mild detergent to clean if there is too much dust.

Note:
The sweat from your hand may erode plating surface, your nail may scrape dome cover result in blur image.

4.2 Problems and Solutions

SYMPTOM

CAUSE

SOLUTION

Red LED is not on.
z

24V AC does not apply to

the power. Or connection is
too loose.

z

Power off or Transformer

problem.

z

Check 24V AC power is

connected or properly
earthed.

z

Check power supply condition

or check 24V transformer.

No self-diagnosis,
no video signal
when I connect
dome to power.

Red LED light is on
z

24V AC power is low

z

Something wrong with power
socket.

z

Use multimeter to check

dome load.

z

Please contact retailer to
replace power socket.

Power supply is inadequate.

Replace power socket.

No self diagnosis.
There is a noise

Mechanical malfunction.

Need electrical engineer help.

Video signal loss
occurs in high speed
rotation.

Power supply is not sufficient

Replace power socket.

Circuit connection is too loose. Connect

tightly.

Video signal is not
successive

Video switch or power problem

Need electrical engineer help.

Focus is in manual mode.

Control manually.

Video is not clear.

Dome cover is dirty.

Wash dome cover

During camera
switch, there is a tilt
movement in the
monitor.

Camera power is not in the same
Phase.

When several domes are
connected to one transformer,
please connect the transformer
output cable to the domes’ same
side.