Triggering or clearing alarm outputs manually, Setting up system notifications – Interlogix TruVision DVR 12 User Manual User Manual

Page 38

Advertising
background image

36

TruVision DVR 12 User Manual

Triggering or clearing alarm outputs
manually

When an alarm is activated, the recorder can be set up so that the alarm must be
manually acknowledged in order to be silenced. See “Setting up external alarms”
on page 34 for information on setting up an alarm to be manually cleared.

All user levels (administrator, manager, and operator) can manually acknowledge
an alarm.

To trigger or clear alarm outputs manually:

1. From the menu toolbar, click

Alarm Settings

> Alarm Output.

2. Click the

Manual Alarm

tab.

3. Select the desired alarm output and click one of the following buttons:

• Trigger / Clear: Trigger an alarm output or stop an alarm output.
• Trigger All: Trigger all alarm outputs at once. This action could be done,

for example, when you need to test them.

• Clear All: Stop all alarm outputs at once.

4. Click

Back

to return to live view. The alarm is silenced.

- Or -

1. Press the

Alarm

button on the front panel or remote control. The alarm is

silenced.

Setting up system notifications

Setting up system notifications instructs the recorder to alert you when irregular
events occur and how to alert you to the event.

You can quickly check the system status by looking at the status LEDs on the
front panel. When there is an irregular event with the system, an icon appears on
screen to also alert you. See “Status information” on page 65 for further
information.

The types of system notifications include:

• HDD Full: An installed HDD is full (overwrite option is disabled).

• HDD Error: Errors occurred while files were being written to the HDD, no

HDD installed or HDD had failed to initialize.

• Network Disconnected: Disconnected network cable.

• IP Conflicted: Conflict in IP address setting.

• Illegal Login: Wrong user ID or password used.

• Input/output Video Standards Mismatch: I/O video standards do not

match.