Configuring multicast, Configuring the server and http ports, Configuring the rtsp service port – Interlogix TruVision DVR 12 User Manual User Manual
Page 48
46
TruVision DVR 12 User Manual
Alarm host IP represents the IP of the remote PC where the Network Video
Surveillance software installed. The alarm host port value must be the same
as software’s alarm monitor port. Up to three alarm hosts can be set. For
each alarm host, the default port is 5001, 5002, and 5003.
3. Click
Apply
to save the settings.
Configuring multicast
Setting up multicasting resolves limitation issues when streaming videos through
a network access device. A multicast address spans the Class-D IP range of
224.0.0.0 to 239.255.255.255. We recommend that the IP address range of
239.252.0.0 to 239.255.255.255 be used.
To set up multicasting:
1. From the menu toolbar, click
Network Settings
>
More Settings
.
2. Enter a Multicast IP address.
Note:
When adding a device to the Network Video Surveillance software, the
multicast address must be the same as the recorder’s multicast IP.
3. Click
Apply
to save the settings.
Configuring the server and HTTP ports
You can change the server and HTTP ports from the default settings in the
Network Settings window. The default server port is 8000 while that of the default
HTTP port is 80.
Note:
The server port has a port range of 2000 to 65535 and is used for remote
client software access. The HTTP port is used for remote internet browser
access.
To change the default ports:
1. From the menu toolbar, click
Network Settings
>
More Settings
.
2. Enter the new Server Port and HTTP Port values.
Configuring the RTSP service port
The RTSP (Real Time Streaming Protocol) is a network control protocol
designed for use in entertainment and communications systems to control
streaming media servers.