Interlogix 2100 Series User Manual

2100 series, Installation instructions, Mounting

Advertising
background image

3.44"

8.73 cm

2.50"

5.75 cm

1.25"

3.19 cm

0.75"

1.91 cm

1.63"

4.13 cm

2.13"

5.40 cm

0.56"

1.43 cm

0.69"

1.75 cm

2.56"

6.50 cm

0.44"

1.11 cm

Movable portion of unit to be protected

Movable portion of unit to be protected

Stationary
post

Ring or eye
bolt on wall

To alarm control

To alarm control

Mounting

Mount the magnet section on the object to be protected.
Once the magnet is installed, place the cover over the
magnet and screw it to the surface. Use #10 screws to
secure both units. Mount the cord section with clamps so
the cord will pull straight out of the magnet housing when
it reaches the end of the cord. Make sure it has the correct
slack and loop so it will not hang up on anything as the
protected object is moved.

Alternate mounting

Loop the cord through the object being protected or
through a stationary object.

CAUTION

If the alternate mounting is used, make sure
the alarm owner is warned that they could
break the pull-apart if they do not release it
before moving the protected object.

Lead functions

Form A

Model 2105-A, use black leads

Form C

Model 2107-A

Lead color

Function

Black

Common

White

Closed Loop (NO)

Red

Open Loop (NC)

Magnet cover

Magnet

Switch

2100 Series

Magnapull Heavy Duty
Magnetic Contact with Pull-Apart Cords

Models: 2105-A, 2107-A